MétaCan
Menu
← Back to cohort
Record W3208714659 · doi:10.3390/s21217248

A Generic Sequential Stimulation Adapter for Reducing Muscle Fatigue during Functional Electrical Stimulation

2021· article· en· W3208714659 on OpenAlexafffund
Gongkai Ye, Saima Ali, Austin J. Bergquist, Miloš R. Popović, Kei Masani

Bibliographic record

VenueSensors · 2021
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsUniversity of TorontoToronto Rehabilitation InstituteUniversity Health Network
FundersCanadian Institutes of Health Research
KeywordsAdapter (computing)Functional electrical stimulationStimulationPulse (music)Rehabilitation engineeringBiomedical engineeringComputer scienceSIGNAL (programming language)MedicineVoltageEngineeringComputer hardwareElectrical engineeringRehabilitationInternal medicinePhysical therapy

Abstract

fetched live from OpenAlex

BACKGROUND: Clinical applications of conventional functional electrical stimulation (FES) administered via a single electrode are limited by rapid onset neuromuscular fatigue. "Sequential" (SEQ) stimulation, involving the rotation of pulses between multiple active electrodes, has been shown to reduce fatigue compared to conventional FES. However, there has been limited adoption of SEQ in research and clinical settings. METHODS: The SEQ adapter is a small, battery-powered device that transforms the output of any commercially available electrical stimulator into SEQ stimulation. We examined the output of the adaptor across a range of clinically relevant stimulation pulse parameters to verify the signal integrity preservation ability of the SEQ adapter. Pulse frequency, amplitude, and duration were varied across discrete states between 4 and 200 Hz, 10 and100 mA, and 50 and 2000 μs, respectively. RESULTS: A total of 420 trials were conducted, with 80 stimulation pulses per trial. The SEQ adapter demonstrated excellent preservation of signal integrity, matching the pulse characteristics of the originating stimulator within 1% error. The SEQ adapter operates as expected at pulse frequencies up to 160 Hz, failing at a frequency of 200 Hz. CONCLUSION: The SEQ adapter represents an effective and low-cost solution to increase the utilization of SEQ in existing rehabilitation paradigms.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.246
Teacher spread0.208 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueSensors→Same topicMuscle activation and electromyography studies→French-language works237,207→