MétaCan
Menu
Back to cohort
Record W3209589623 · doi:10.1117/1.jmi.8.5.052115

Flat-panel conebeam CT in the clinic: history and current state

2021· article· en· W3209589623 on OpenAlexfundno aff
Rebecca Fahrig, David A. Jaffray, Ioannis Sechopoulos, J. Webster Stayman

Bibliographic record

VenueJournal of Medical Imaging · 2021
Typearticle
Languageen
FieldDentistry
TopicDental Radiography and Imaging
Canadian institutionsnot available
FundersRadboud Universitair Medisch CentrumUniversity of TorontoUniversity of Texas MD Anderson Cancer CenterUniversity of TwenteGeorgia Institute of TechnologyJohns Hopkins UniversityRadboud UniversiteitEmory University
KeywordsMedicineFlat panel detectorDigital radiographyFlat panelMedical physicsImage qualityHigh resolutionNuclear medicineScannerRadiographyRadiologyComputer scienceDetectorArtificial intelligenceComputer graphics (images)Image (mathematics)

Abstract

fetched live from OpenAlex

), for visualization of small contrast-filled vessels, bones, or teeth, was an imaging requirement that could not be met by the contemporaneous CT scanners. However, the use of nonlinear imagers, e.g., x-ray image intensifiers, limited the clinical utility of the earliest diagnostic conebeam CT systems. The development of consumer-electronics large-area displays provided a technical foundation that was leveraged in the 1990s to first produce large-area digital x-ray detectors for use in radiography and then compact flat panels suitable for high-resolution and high-frame-rate conebeam CT. In this review, we show the concurrent evolution of digital flat panel (DFP) technology and clinical conebeam CT. We give a brief summary of conebeam CT reconstruction, followed by a brief review of the correction approaches for DFP-specific artifacts. The historical development and current status of flat-panel conebeam CT in four clinical areas-breast, fixed C-arm, image-guided radiation therapy, and extremity/head-is presented. Advances in DFP technology over the past two decades have led to improved visualization of high-contrast, high-resolution clinical tasks, and image quality now approaches the soft-tissue contrast resolution that is the standard in clinical CT. Future technical developments in DFPs will enable an even broader range of clinical applications; research in the arena of flat-panel CT shows no signs of slowing down.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.004
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.004
Science and technology studies0.0010.003
Scholarly communication0.0020.003
Open science0.0010.001
Research integrity0.0020.004
Insufficient payload (model declined to judge)0.0040.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.333
Teacher spread0.296 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations39
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Medical ImagingSame topicDental Radiography and ImagingFrench-language works237,207