MétaCan
Menu
Back to cohort
Record W3209638285 · doi:10.22374/jclrs.v5i1.43

MICROBIAL BIOBURDEN OF ORTHOKERATOLOGY AND HYDROGEL CONTACT LENSES AND STORAGE CASES USING A HYDROGEN-PEROXIDE DISINFECTING SYSTEM

2021· article· en· W3209638285 on OpenAlexvenueno aff
Ananya Datta, Erin S. Tomiyama, Kathryn Richdale

Bibliographic record

VenueJournal of Contact lens Research and Science · 2021
Typearticle
Languageen
FieldMedicine
TopicCorneal surgery and disorders
Canadian institutionsnot available
Fundersnot available
KeywordsContact lensBioburdenVialMedicineContaminationHydrogen peroxideThimerosalOphthalmologySurgeryDermatologyChemistryBiologyChromatography

Abstract

fetched live from OpenAlex

Background and objective: The fitting of orthokeratology (ortho-k) and multifocal soft contact lenses (SCL) is becoming increasingly popular worldwide for reducing the rate of myopia progression. However, overnight wear use of lenses and microbial contamination of contact lenses and storage vials has been shown to increase the risk of corneal inflammatory and infiltrative events (CIEs). Therefore, we conducted a pilot study to compare the rate, level, and type of microbial contamination of contact lenses and storage vialswhen participants wear ortho-k and SCL in combination with a hydrogen-peroxide disinfecting system. Material and Methods: A prospective, single-centre, randomized, crossover study was conducted to evalu-ate the rate and level of contact lens and storage vials contamination during the use of ortho-k and SCL along with a hydrogen-peroxide disinfecting solution over two 10 day wearing periods. Ocular signs and symptoms were assessed during lens wear at baseline and after each wearing period. In addition, contact lens and storage vials were collected, and the type and amount of microbial contamination were evaluated using viable culture and standard identification methods.Results: Twenty-five adults were enrolled, and 21 completed the study. One (5%) ortho-k lens, five (24%) ortho-k storage vials, one (5%) SCL and one (5%) SCL storage vial were contaminated (P > 0.05), predominantly with Gram-positive bacteria. None of the participants had contamination with both ortho-k and SCL. No significant differences were found between the ocular signs, including conjunctival redness and roughness, or conjunctival or corneal staining (all P > 0.05), irrespective of using ortho-k or SCL. Conclusion: This study provides the first data that directly compares microbial contamination of ortho-K versus SCL in patients using a hydrogen-peroxide disinfection system. However, the overall microbial contamination rate of contact lens storage vials was much lower (30%) than the previously reported study with ortho-k lens wear. The results support conducting a larger clinical trial designed to understand differences in microbial contamination with different lens materials and modalities.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.225
Threshold uncertainty score0.348

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.084
GPT teacher head0.362
Teacher spread0.278 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Contact lens Research and ScienceSame topicCorneal surgery and disordersFrench-language works237,207