MétaCan
Menu
Back to cohort
Record W3209697514 · doi:10.1016/j.xjon.2020.12.024

Iatrogenic left ventricular rupture. Remain inventive!

2021· article· en· W3209697514 on OpenAlexaboutno aff
Manuel J. Antunes

Bibliographic record

VenueJTCVS Open · 2021
Typearticle
Languageen
FieldMedicine
TopicCardiac Structural Anomalies and Repair
Canadian institutionsnot available
Fundersnot available
KeywordsConflict of interestScopusMedicineLetter to the editorCardiologyPolitical scienceLawMEDLINE

Abstract

fetched live from OpenAlex

The author reported no conflicts of interest.The Journal policy requires editors and reviewers to disclose conflicts of interest and to decline handling or reviewing manuscripts for which they may have a conflict of interest. The editors and reviewers of this article have no conflicts of interest. The author reported no conflicts of interest. The Journal policy requires editors and reviewers to disclose conflicts of interest and to decline handling or reviewing manuscripts for which they may have a conflict of interest. The editors and reviewers of this article have no conflicts of interest. I read with much interest the Invited Expert Opinion on “Left Ventricular Rupture After Mitral Valve Replacement” by Dr Tirone David in the September issue of the JTCVS Open.1David T.E. Left ventricular rupture after mitral valve replacement.JTCVS Open. 2020; 3: 48-49Abstract Full Text Full Text PDF Scopus (2) Google Scholar It emphasizes the deadly nature of the complication and the technical complexity of the repair, a task sometimes impossible. Often, the external site of rupture is situated far away from the originating internal point that, however, is not always identifiable. Also, there are some other causes of iatrogenic left ventricular rupture. I write this letter to bring to the attention of the readers of the Journal one case that, in my opinion, highlights the difficulties identified by Dr David and was treated by a previously undescribed approach (however recently reported elsewhere).2Antunes M.J. Bernardo J.E. Pinto C.S. A gauze-pad wrapping of the heart can save a patient's life.Braz J Cardiovasc Surg. 2021; 36: 834-835Crossref PubMed Scopus (1) Google Scholar I refer to a 79-year-old female patient who had surgery for severe mitral valve regurgitation caused by posterior leaflet prolapse and calcified annulus. She also had hypertrophic obstructive cardiomyopathy with a left ventricular outflow tract gradient of 45 to 50 mm Hg. The cardiomyopathy was initially addressed with an extended myectomy, performed from the aortic root. After unsuccessful repair that resulted in systolic anterior motion, the mitral valve was replaced by a bioprosthesis, with partial preservation of the posterior leaflet. The patient had an uneventful immediate postoperative course, but on the second day there was a sudden severe drainage of blood, which prompted emergency pericardial exploration, where a large subepicardial hematoma was identified in the posterior left ventricular wall. Having suspected rupture of the atrioventricular junction, cardiopulmonary bypass was initiated, the left atrium was opened, and the mitral prosthesis excised from its annular implantation. No rupture could be identified at this place. An alternative diagnosis was rupture at the site of the myectomy, but neither this nor any other site was internally identified. The mitral prosthesis was reimplanted and the atrium closed. As the hemorrhage from the back of the heart persisted, an attempt was made at controlling it from the epicardial side by using a patch of TachoSil (human fibrinogen + thrombin; Nycomed, Baxter, Zurich, Switzerland) to fill the subepicardial hematoma cavity and covering the surface with SURGICEL (Ethicon, Somerville, NJ). This was repeatedly unsuccessful. In despair, a double-layer ordinary surgical gauze pad was used to completely wrap the ventricular wall, which resulted in immediate cessation of the bleeding. The gauze pad was left in place for planned removal later, which was done on the 10th day. The patient had an uneventful recovery and was discharged home 7 days later. This case reminds me of a Brazilian surgeon and friend who, also in absolute despair, in a similar case, used common-use superglue (cyanoacrylate) to achieve adherence of a bovine pericardial patch to the epicardium. These cases highlight the need to exercise some surgical inventiveness spirit when all else fails. Left ventricular rupture after mitral valve replacementJTCVS OpenVol. 3PreviewVentricular rupture after mitral valve replacement (MVR) is a rare and often a fatal complication of this operation. This problem was first presented at the 39th Annual Meeting of the American College Chest Physicians in Toronto, on October 22, 1973, by Dr Robert L. Treasure and colleagues.1 Those investigators collected 7 cases from 3 hospitals and, based on the site of the ventricular tear, they classified the ventricular ruptures in type 1 (atrioventricular groove) and type 2 (midventricular wall). Full-Text PDF Open Access

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.288
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.290
Teacher spread0.274 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJTCVS OpenSame topicCardiac Structural Anomalies and RepairFrench-language works237,207