Correlation of Plasma Temperature, Charged Particle Generation and X-Ray Emission From a Dense Plasma Focus
Bibliographic record
Abstract
Experimental studies have been carried out on a low energy (2kJ) dense plasma focus (DPF) device1, 2at the University of Saskatchewan to study the correlations among various parameters including the electron temperature, charged particle emission and X -ray radiation. The DPF is filled with Argon gas at various pressures. The electron temperature in the pinching plasma is measured using a diode array (4 discrete diodes) with cobalt filters of chosen thickness in front of them so the transmission of the copper line emission is minimized. The electron temperatures up to 7 ke V have been measured. A Faraday cup with a fast response time is placed in front of the anode to measure the ion beam intensity. The electrons through the hollow anode are collected by a metal plate connected to the ground and its corresponding current is measured using a Pearson current probe. The hard x-ray is measured using a photomultiplier tube with a plastic scintillator placed in front of it.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".