MétaCan
Menu
Back to cohort
Record W3210903829 · doi:10.1186/s13550-021-00856-w

[68Ga]Ga-4HMSA a promising new PET tracer for imaging inflammation

2021· article· en· W3210903829 on OpenAlexafffund
Shigufa Kahn Ali, Samia Aı̈t-Mohand, Véronique Dumulon‐Perreault, Brigitte Guérin

Bibliographic record

VenueEJNMMI Research · 2021
Typearticle
Languageen
FieldMedicine
TopicRadiopharmaceutical Chemistry and Applications
Canadian institutionsUniversité de Sherbrooke
FundersFonds de Recherche du Québec - SantéNatural Sciences and Engineering Research Council of CanadaUniversité de Sherbrooke
KeywordsMedicineCardiac imagingInflammationPositron emission tomographyMedical physicsNuclear medicineRadiologyInternal medicine

Abstract

fetched live from OpenAlex

Abstract Background Imaging diagnosis of inflammation has been challenging for many years. Inflammation imaging agents commonly used in nuclear medicine, such as [ 67 Ga]Ga-citrate and 2-deoxy-2-[ 18 F]fluoro- d -glucose ([ 18 F]FDG) showed some limitations. The identification of a radiotracer with high specificity and low radiation dose is clinically important. With the commercialization of 68 Ge/ 68 Ga generators and the high 68 Ga cyclotron production capacity, the study of 68 Ga-based tracer for inflammation has increased and shown good potential. In the present work, we report the synthesis of 4HMSA, a new acyclic chelator, and its first investigation for 68 Ga complexation and as a new positron emission tomography (PET) imaging agent of inflammation in comparison to [ 68 Ga]Ga-citrate. Results The present experimental studies have shown that the novel [ 68 Ga]Ga-4HMSA is stable allowing imaging of inflammation in a preclinical model of adjuvant- and pathogen-based inflammation involving intraplantar injection of complete Freund’s adjuvant (CFA). We also found that [ 68 Ga]Ga-4HMSA displayed similar uptakes in the inflamed paw than [ 68 Ga]Ga-citrate, which are superior compared to those of contralateral (non-injected) paws at days 1–3 from PET imaging. [ 68 Ga]Ga-citrate accumulated in the upper body of the animal such as the liver, lungs and the heart, whereas the [ 68 Ga]Ga-4HMSA revealed low uptakes in the majority of the organs and was cleared relatively rapidly from blood circulation through the kidneys and bladder. Conclusion The results highlight the potential of [ 68 Ga]Ga-4HMSA as an interesting alternative to [ 68 Ga]Ga-citrate for inflammation imaging by PET. The new PET tracer also offers additional advantages than [ 68 Ga]Ga-citrate in term of dosimetry and lower overall background activity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.221
Threshold uncertainty score0.594

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.201
GPT teacher head0.518
Teacher spread0.317 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueEJNMMI ResearchSame topicRadiopharmaceutical Chemistry and ApplicationsFrench-language works237,207