Reducing the Energy Consumption by Using Floor Heating with Phase Change Materials in the Toronto Climate
Bibliographic record
Abstract
This major research project focuses on reducing the energy consumption, by modelling a radiant floor heating system with phase change materials, in the Toronto climate. Computer generated simulations were performed using DesignBuilder software, using an example of a typical condominium in Toronto .Two south facing suites and two north facing suites were investigated. Of those suites, one north facing suite had PCM below the finished floor, as well as one south facing suite. The objective of these simulations was to determine the impact of using PCM in the condo suites. Three different types of PCM were used, in order to determine which type had the biggest energy savings. The PCMs were M91/Q21, M51/Q21 and M27/Q21. The final results showed that the suites with the M27/Q21 PCM had the lowest energy usage. A cost savings comparison was performed based on the rate of energy used and the cost of the energy, provided by the Ontario Energy Board.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".