MétaCan
Menu
Back to cohort
Record W3212546807 · doi:10.1016/j.hroo.2021.11.009

Novel ventricular tachyarrhythmia detection enhancement detects undertreated life-threatening arrhythmias

2021· article· en· W3212546807 on OpenAlexaff
Bruce L. Wilkoff, Laurence D. Sterns, Michael S. Katcher, Gaurav A. Upadhyay, Peter Seizer, Chaoyi Kang, J.L. Rhude, Kevin J. Davis, Avi Fischer

Bibliographic record

VenueHeart Rhythm O2 · 2021
Typearticle
Languageen
FieldMedicine
TopicCardiac electrophysiology and arrhythmias
Canadian institutionsRoyal Jubilee Hospital
FundersBiotronikPhilipsMedtronicAbbott Laboratories
KeywordsMedicineImplantable cardioverter-defibrillatorCardiologyVentricular fibrillationInternal medicine

Abstract

fetched live from OpenAlex

BackgroundVentricular tachyarrhythmias (VTA) with low and varying signal amplitudes and morphologies may not be successfully identified utilizing traditional implantable cardioverter-defibrillator algorithms.ObjectiveDevelop and validate a novel algorithm (VF Therapy Assurance, VFTA) to improve detection and timely delivery of high-voltage therapy (HVT) for these arrhythmias.MethodsArrhythmia detection was simulated on recorded VTA electrograms (EGMs) utilizing Abbott’s Merlin.net database. EGMs where an HVT occurred only when VFTA was enabled, or where VFTA provided an HVT >30 seconds earlier than without VFTA, were readjudicated with physician review. As VFTA never prevents detection or therapy, EGMs where VFTA did not activate or alter HVT were not adjudicated.ResultsAmong 564,353 recorded VTA EGMs from 20,000 devices, VFTA altered HVT in 105 EGMs from 67 devices. Physician adjudication determined that 81.9% (86/105) of these EGMs were true undertreated VTA episodes and would have received appropriate HVT with VFTA enabled. Furthermore, 65% of the episodes (56/86) were ventricular fibrillation, were polymorphic, did not self-terminate during the recording window, or were not amenable antitachycardia pacing. Of those, 87.5% (49/56) would not have elicited HVT without VFTA. Overall, VFTA provided new or earlier appropriate HVT in 0.27% (53/20,000) of devices with an increase in inappropriate HVT in 0.07% (14/20,000) devices.ConclusionThe VFTA algorithm successfully identifies VTA missed by traditional detection algorithms, owing to undersensed ventricular signals resulting in the rate falling below the programmed detection rate. The use of VFTA increases the likelihood of delivering life-saving HVT. Ventricular tachyarrhythmias (VTA) with low and varying signal amplitudes and morphologies may not be successfully identified utilizing traditional implantable cardioverter-defibrillator algorithms. Develop and validate a novel algorithm (VF Therapy Assurance, VFTA) to improve detection and timely delivery of high-voltage therapy (HVT) for these arrhythmias. Arrhythmia detection was simulated on recorded VTA electrograms (EGMs) utilizing Abbott’s Merlin.net database. EGMs where an HVT occurred only when VFTA was enabled, or where VFTA provided an HVT >30 seconds earlier than without VFTA, were readjudicated with physician review. As VFTA never prevents detection or therapy, EGMs where VFTA did not activate or alter HVT were not adjudicated. Among 564,353 recorded VTA EGMs from 20,000 devices, VFTA altered HVT in 105 EGMs from 67 devices. Physician adjudication determined that 81.9% (86/105) of these EGMs were true undertreated VTA episodes and would have received appropriate HVT with VFTA enabled. Furthermore, 65% of the episodes (56/86) were ventricular fibrillation, were polymorphic, did not self-terminate during the recording window, or were not amenable antitachycardia pacing. Of those, 87.5% (49/56) would not have elicited HVT without VFTA. Overall, VFTA provided new or earlier appropriate HVT in 0.27% (53/20,000) of devices with an increase in inappropriate HVT in 0.07% (14/20,000) devices. The VFTA algorithm successfully identifies VTA missed by traditional detection algorithms, owing to undersensed ventricular signals resulting in the rate falling below the programmed detection rate. The use of VFTA increases the likelihood of delivering life-saving HVT.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.086
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.255
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2021
Admission routes1
Has abstractyes