MétaCan
Menu
Back to cohort
Record W3213091555 · doi:10.32920/ryerson.14660700.v1

Investigation of installation characteristics of ASTM-F1852 twist-off type tension control fasteners under various temperature levels

2021· preprint· en· W3213091555 on OpenAlexafffund
Hamidreza Akhlagh-Nejat

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldEngineering
TopicMechanical stress and fatigue analysis
Canadian institutionsToronto Metropolitan UniversityBrampton Civic Hospital
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institute of Steel Construction
KeywordsTwistTorqueUltimate tensile strengthStructural engineeringThread (computing)Tension (geology)Bolted jointMechanical engineeringEngineeringMaterials scienceComposite materialMathematics

Abstract

fetched live from OpenAlex

Twist-off tension control method is one of the available and recognized methods for bold pretensioning in the steel construction industry. Twist-off tension control bolts are commonly used in steel construction because they are fast, easy to utilize and convenient to inspect. Twist-off tension control is characterized by a spline at the end which can shear off at a circular notch (torque control groove) when the required preload is achieved. Preload in twist-off assemblies are based on torque control that can be affected by friction between components of the bolt assembly. This friction can be affected by any environmental condition or material property such as bolt material strength, geometric properties of the assembly, thread and lubrication conditions of the nut and bolt and installation temperature. Earlier studies have shown that twist-off bolt assemblies used in the field and left exposed to weather for a period of time prior to applying the pretensioning force, demonstrate degradation in the achieved tensile force. This phenomenon formed a series of research concerning effects of moisture, delay installation and temperature levels on the achieved tensile force in the bolt. The effect of temperature levels in degradation of achieved tensile force forms the principle parameter of concern in the current research. Results showed that the twist-off bolt assemblies failed to achieve the minimum specified pretension for installation temperatures less than 0°C. Empirical equations were developed to provide engineers and fabricators of an estimate of the reduction in the achieved pretensioning force in twist-off bolt assemblies with the change in temperature levels at time of installation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.222
Teacher spread0.196 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes2
Has abstractyes

Explore more

Same topicMechanical stress and fatigue analysisFrench-language works237,207