Open Circuit Fault-tolerant Operation of a Modified Hybrid String Inverter/Rectifier Leg
Bibliographic record
Abstract
Failures in bidirectional power converters can be critical and challenging especially in the energy storage applications due to their nature and high replacement costs. This paper presents a modified topology based on the 6-switch hybrid string converter. In the modified structure, the diodes have been replaced by the active switches to add switching redundancy and to provide open circuit fault-tolerant control while improving the efficiency by means of synchronous rectification. As a result, post fault operation at full power can be performed preventing the power to be interrupted in case of any OCF incidents. The processor-in-the-loop (PIL) test results have been provided on a 1 kW 400VDC/700VDC converter to demonstrate the performance of the proposed converter along with the fault-tolerant control. A 1kW 400VDC/700VDC prototype has been designed to verify the feasibility of the proposed concept.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".