MétaCan
Menu
Back to cohort
Record W3213769499 · doi:10.1186/s40463-021-00541-x

Navigation and non-navigation CT scan of the sinuses: Comparison of the effective doses of radiation in children and adults

2021· article· en· W3213769499 on OpenAlexaff
Noémie Villemure‐Poliquin, Mario Chrétien, Jacques Leclerc

Bibliographic record

VenueJournal of Otolaryngology - Head and Neck Surgery · 2021
Typearticle
Languageen
FieldMedicine
TopicSinusitis and nasal conditions
Canadian institutionsUniversité Laval
Fundersnot available
KeywordsMedicineNuclear medicineRadiologyRadiation exposureSinus (botany)Paranasal sinusesPopulationMaxillary sinusCohortSurgeryInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: The advent of 3D navigation imaging has opened new borders to the endoscopic surgical approaches of naso-sinusal inflammatory and neoplastic disease. This technology has gained in popularity among otolaryngologists for endoscopic sinus and skull base surgeries in both adults and children. However, the increased tissue radiation required for data acquisition associated with 3D navigation protocols CT scans is a source of concern because of its potential health hazards. We aimed to compare the effective doses of radiation between 3D navigation protocols and standard protocols for sinus computed tomography (CT) scans for both the adult and pediatric population. METHODS: We performed a retrospective cohort study through electronic chart review of patients undergoing sinus CT scans (standard and 3D navigation protocols) from May 2019 to December 2019 using a Siemens Drive (VA62A) CT scanner. The effective dose of radiation was calculated in mSv for all exams. Average irradiation doses were compared using a Student's T-Test or a Kruskall-Wallis test when appropriate. RESULTS: A total of 115 CT scans were selected for analysis, of which 47 were standard protocols and 68 were 3D navigation protocols CT scans. Among these, 31 exams were performed on children and 84 exams on adults. For the total population, mean effective dose in the non-navigation CT scans was 0.37 mSv (SD: 0.16, N = 47) and mean effective dose in the 3D navigation sinus CT group was 2.33 mSv (SD: 0.45, N = 68). The mean difference between the two groups was statistically significant 1.97 mSv (CI 95% - 2.1 to - 1.83; P < 0.0001). There was a sixfold increase in radiation with utilization of 3D navigation protocols. The ratio was identical when the pediatric as well as the adult subset of patients were analyzed. CONCLUSION: In our center, utilization of 3D navigation sinus CT protocols significantly increases radiation exposure. Otolaryngologists should be aware of this significant increase and should attempt to decrease the radiation exposure of their patients by limiting unnecessary scan orders and by evaluating 3D acquisition protocols locally with radiation physicists. LEVEL OF EVIDENCE: Level IV.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.006
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.274
Teacher spread0.265 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Otolaryngology - Head and Neck SurgerySame topicSinusitis and nasal conditionsFrench-language works237,207