MétaCan
Menu
Back to cohort
Record W3214633058 · doi:10.1007/s10909-022-02843-4

Design of the SPT-SLIM Focal Plane: A Spectroscopic Imaging Array for the South Pole Telescope

2022· preprint· en· W3214633058 on OpenAlexaff
P. S. Barry, A. J. Anderson, B. A. Benson, J. E. Carlstrom, T. Cecil, C. L. Chang, M. Dobbs, M. Hollister, K. S. Karkare, Garrett K. Keating, Daniel P. Marrone, J. J. McMahon, J. Montgomery, Z. Pan, G. Robson, M. Rouble, E. Shirokoff, Graeme Smecher

Bibliographic record

VenueJournal of Low Temperature Physics · 2022
Typepreprint
Languageen
FieldPhysics and Astronomy
TopicSuperconducting and THz Device Technology
Canadian institutionsThree-Speed Logic (Canada)McGill University
FundersArgonne National LaboratoryBasic Energy SciencesDivision of Astronomical SciencesFermilabLaboratory Directed Research and DevelopmentHigh Energy PhysicsU.S. Department of EnergyOffice of ScienceNational Science Foundation
KeywordsCardinal pointSpectrometerPhysicsTelescopeOpticsDetectorMicrostripLarge formatImaging spectrometerPixelMultiplexingSouth Pole TelescopeWindow (computing)Field of viewRemote sensingTelecommunicationsComputer scienceGeologyCosmic microwave background

Abstract

fetched live from OpenAlex

Abstract The Summertime Line Intensity Mapper (SLIM) is a mm-wave line-intensity mapping (mm-LIM) experiment for the South Pole Telescope (SPT). The goal of SPT-SLIM is to serve as a technical and scientific pathfinder for the demonstration of the suitability and in-field performance of multi-pixel superconducting filterbank spectrometers for future mm-LIM experiments. Scheduled to deploy in the 2023-24 austral summer, the SPT-SLIM focal plane will include 18 dual-polarisation pixels, each coupled to an $$R = \lambda / \Delta \lambda = 300$$ R = λ / Δ λ = 300 thin-film microstrip filterbank spectrometer that spans the 2 mm atmospheric window (120–180 GHz). Each individual spectral channel feeds a microstrip-coupled lumped-element kinetic inductance detector, which provides the highly multiplexed readout for the 10k detectors needed for SPT-SLIM. Here, we present an overview of the preliminary design of key aspects of the SPT-SLIM focal plane array, a description of the detector architecture and predicted performance, and initial test results that will be used to inform the final design of the SPT-SLIM spectrometer array.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.008
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0050.004

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.256
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Low Temperature PhysicsSame topicSuperconducting and THz Device TechnologyFrench-language works237,207