MétaCan
Menu
Back to cohort

Validation of a magnetic resonance imaging based method to study passive knee laxity: An in-situ study

2021· article· en· W3215078577 on OpenAlexafffund
Jessica Küpper, Nazanin Sinaei, Lindsey Westover, Payam Zandiyeh, Janet L. Ronsky

Bibliographic record

VenueMedical Engineering & Physics · 2021
Typearticle
Languageen
FieldMedicine
TopicKnee injuries and reconstruction techniques
Canadian institutionsUniversity of AlbertaUniversity of Calgary
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsGold standard (test)Magnetic resonance imagingCadaveric spasmStiffnessBiomedical engineeringKnee JointRepeatabilityMaterials scienceNuclear medicineMedicineSurgeryMathematicsRadiology

Abstract

fetched live from OpenAlex

Knee laxity can be described as an increased anterior tibial translation (ATT) or decreased stiffness of the tibiofemoral joint under an applied force. Küpper et al. (2013, 2016) and Westover et al. (2016) previously developed and reported on a magnetic resonance (MR)-based in vivo measure of knee laxity. In this study, the application of an in situ knee loading apparatus (ISKLA) is presented as a step toward validating the MR-based methodology for measuring ATT and stiffness. The ISKLA is designed to measure these outcome variables using MR imaging and is validated against a gold-standard ElectroForce mechanical test instrument (TA Instruments 3550). Accuracy was assessed through an in situ experimental setup by testing four cadaveric specimens with both the MR-based methodology and in the ElectroForce system. The outcome of the current study showed that the MR-based ATTs and stiffness measurements using the ISKLA were within 1.44-2.10 mm and 0.16-6.14 N/mm, respectively, of the corresponding values measured by the gold standard system. An excellent ICC was observed for ATT (0.97) and good ICC for stiffness (0.87) between the MR and ElectroForce-based systems across all target force levels. These findings suggest that the MR-based approach can be used with satisfactory accuracy and correlation to the gold standard measure.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.037

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0070.008
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.296
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueMedical Engineering & PhysicsSame topicKnee injuries and reconstruction techniquesFrench-language works237,207