MétaCan
Menu
Back to cohort
Record W3215700975 · doi:10.3390/diagnostics11122179

The Effect of Limiting the Scan Range of Computed Tomography Pulmonary Angiography (to Reduce Radiation Exposure) on the Detection of Pulmonary Embolism: A Systematic Review

2021· review· en· W3215700975 on OpenAlexaboutno aff
Amayar Zaw, Rebecca Nguyen, Leon Lam, Anthony Kaplan, Claudia C. Dobler

Bibliographic record

VenueDiagnostics · 2021
Typereview
Languageen
FieldMedicine
TopicVenous Thromboembolism Diagnosis and Management
Canadian institutionsnot available
FundersNational Health and Medical Research Council
KeywordsPulmonary embolismLimitingRadiologyMedicinePulmonary angiographyComputed tomographyRadiation doseRadiation exposureAngiographyNuclear medicineInternal medicineEngineering

Abstract

fetched live from OpenAlex

(1) Background: Computed tomography pulmonary angiography (CTPA) is the standard imaging test for the evaluation of acute pulmonary embolism (PE), but it is associated with patients’ exposure to radiation. Studies have suggested that radiation exposure can be reduced without compromising PE detection by limiting the scan range (the z-axis, going from up to down); (2) Methods: A literature search was conducted in MEDLINE and EMBASE on 17 July 2021. Studies were included if they enrolled patients who had undergone a CTPA and described the yield of PE diagnoses, number of missed filling defects and/or other diagnoses using a reduced z-axis in comparison to a full-length scan. To assess risk of bias, we modified an existing risk of bias tools for observational studies, the Newcastle-Ottawa Scale. Results were synthesized in a narrative review. Primary outcomes were the number of missed PE diagnoses (based on at least one filling defect) and filling defects; the secondary outcome was the number of other missed findings; (3) Results: Eleven cohort studies and one case-control study were included reporting on a total of 3955 scans including 1025 scans with a diagnosis of PE. Six different reduced scan ranges were assessed; the most studied was from the top of the aortic arch to below the heart, in which no PEs were missed (seven studies). One sub-segmental PE was missed when the scan coverage was 10 cm starting from the bottom of the aortic arch and 14.7 cm starting from the top of the arch. Five studies that reported on other findings all found that other diagnoses were missed with a reduced z-axis. Most of the included studies had a high risk of bias; (4) Conclusions: CTPA scan coverage reduction from the top of aortic arch to below the heart reduced radiation exposure without affecting PE diagnoses, but studies were generally at high risk of bias.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.014
metaresearch head score (Gemma)0.074
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.014
Threshold uncertainty score0.074

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0140.074
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0090.010
Bibliometrics0.0080.007
Science and technology studies0.0010.001
Scholarly communication0.0030.003
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.286
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueDiagnosticsSame topicVenous Thromboembolism Diagnosis and ManagementFrench-language works237,207