Abstract Portable oxygen concentrators (POCs) are widely used to administer long-term oxygen therapy (LTOT) and employ pulsed delivery modes to conserve oxygen. Efficient pulsed delivery requires that POCs are triggered by patient inhalation. Triggering is known to fail for some patients during periods of quiet breathing, as occurs during sleep. This article describes a new nasal interface designed to improve triggering of pulsed oxygen delivery from POCs. In vitro experiments incorporating realistic nasal airway replicas and simulated breathing were conducted. The pressure monitored via oxygen supply tubing (the signal pressure) was measured over a range of constant inhalation flow rates with the nasal interface inserted into the nares of the nasal airway replicas, and then compared with signal pressures measured for standard and flared nasal cannulas. The triggering efficiency and fraction of inhaled oxygen (FiO2) were next evaluated for the nasal interface and cannulas used with a commercial POC during simulated tidal breathing through the replicas. Higher signal pressures were achieved for the nasal interface than for nasal cannulas at all flow rates studied. The nasal interface triggered pulsed delivery from the POC in cases where nasal cannulas had failed to do so. FiO2 was significantly higher for successful triggering cases than for failed triggering cases. The nasal interface improved triggering of pulsed oxygen delivery from a POC and presents a simple solution that could be used with commercially available POCs to reliably supply oxygen during periods of quiet breathing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.020
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.040
GPT teacher head0.351
Teacher spread0.312 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Medical DevicesSame topicRespiratory Support and MechanismsFrench-language works237,207