Record W3216562593 · doi:10.1002/mp.15373

Superiorization versus regularization: A comparison of algorithms for solving image reconstruction problems with applications in computed tomography

2021· article· en· W3216562593 on OpenAlexafffund
Maria Guenter, Steve M. Collins, A Ogilvy, Warren Hare, Andrew Jirasek

Bibliographic record

VenueMedical Physics · 2021
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversity of British Columbia, Okanagan CampusUniversity of British Columbia
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of British Columbia
KeywordsAlgorithmOverfittingIterative reconstructionImage qualityRegularization (linguistics)Computer scienceMathematicsImage (mathematics)Artificial intelligenceArtificial neural network

Abstract

fetched live from OpenAlex

PURPOSE: A system matrix can be built in order to account for the refractions in an optical computed tomography (CT) system. In order to utilize this system matrix, iterative methods are employed to solve the image reconstruction problem. The purpose of this study is to compare potential iterative algorithms to solve this image reconstruction problem. Comparisons examine both solution time and the quality of the reconstructed image. While our work is motivated by optical CT, the results can be extended more generally to CT. METHODS: A collection of 21 algorithms for solving the image reconstruction problem were evaluated. Specifically, algorithms using (i) superiorization techniques and (ii) regularization to avoid overfitting were compared. Multiple test problems are investigated using 18 different image phantoms, parallel-beam and fan-beam system matrices, and varying noise levels. Comparison of the algorithms is done using performance profiles on three different performance measures. RESULTS: The results for both the synthetic and clinical test problems show that there is not one single algorithm outperforming all others, but instead a set of top algorithms that give the best values on the performance profiles. When qualitative analyses such as reliance on stopping conditions, number of input parameters, and run time are also considered, FISTA-TV shows slight advantages over the other top algorithms. CONCLUSIONS: There is a set of top algorithms that all show good results in the performance profiles with a mix of superiorized and regularized model algorithms. As to which of these top algorithms outperforms the rest is undetermined and further research needs to be investigated.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.006
Threshold uncertainty score0.033

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.012
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0020.002
Open science0.0010.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.321
Teacher spread0.291 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207