MétaCan
Menu
Back to cohort
Record W3216916876 · doi:10.3390/chemosensors9110328

Reconfigurable Modular Platform for Prolonged Sensing of Toxic Gases in Particle Polluted Environments

2021· article· en· W3216916876 on OpenAlexaff
Hamid SadAbadi, Ali Bostani, Amin Esmaeili

Bibliographic record

VenueChemosensors · 2021
Typearticle
Languageen
FieldEngineering
TopicMicrowave and Dielectric Measurement Techniques
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsResonatorMicrowaveMaterials scienceAdsorptionAmmoniaPermittivityFiltration (mathematics)Particle (ecology)OptoelectronicsNanotechnologyChemistryComputer scienceDielectricTelecommunications

Abstract

fetched live from OpenAlex

The prolonged sensing of toxic gases in polluted particles and harsh environments is a challenging task that is also in high demand. In this work, the proof of principle of a sensitive, low-cost, and low-maintenance reconfigurable platform for filter-free and continuous ammonia (NH3) sensing in polluted environments is simulated. The platform can be modified for the detection of various toxic gases and includes three main modules: a microfluidic system for in-line continuous dust filtering; a toxic gas adsorption module; and a low-frequency microwave split-ring resonator (SRR). An inertia-based spiral microfluidic system has been designed and optimized through simulation for the in-line filtration of small particles from the intake air. Zeolite Y is selected as the adsorbent in the adsorption module. The adsorption module is a non-metallic thin tube that is filled with zeolite Y powder and precisely fixed at the drilled through-hole into the 3D microwave system. For the sensing module, a low-frequency three-dimensional (3D) split-ring resonator is proposed and optimally designed. A microwave resonator continuously monitors the permittivity of zeolite Y and can detect small permittivity alterations upon the presence of ammonia in the intake air. The microwave resonator is optimized at a frequency range of 2.5–3 GHz toward the detection of ammonia under different ammonia concentrations from 400 to 2800 ppm. The microwave simulation results show a clear contrast of around 4 MHz that shifts at 2.7 GHz for 400 ppm ammonia concentration. The results show the proof of principle of the proposed microfluidic-microwave platform for toxic gas detection.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.014
Threshold uncertainty score0.483

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.219
Teacher spread0.191 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueChemosensorsSame topicMicrowave and Dielectric Measurement TechniquesFrench-language works237,207