MétaCan
Menu
Back to cohort

Simultaneous Determination of Candesartan and Hydrochlorothiazide in Human Plasma by HPLC-MS/MS

2021· article· en· W3217188055 on OpenAlexaff
P. K. Karnakova, Т. Н. Комаров, O. A. Archakova, D. S. Shchelgacheva, A. V. Aleshina, N. S. Bagaevа, P. A. Karpova, I. E. Shohin

Bibliographic record

VenueDrug development & registration · 2021
Typearticle
Languageen
FieldChemistry
TopicAnalytical Methods in Pharmaceuticals
Canadian institutionsCanadian Public Health Association
Fundersnot available
KeywordsCandesartanHydrochlorothiazideChromatographyChemistryValsartanHigh-performance liquid chromatographyIndapamideFormic acidAngiotensin IIPharmacologyDiureticMedicineInternal medicineBlood pressure

Abstract

fetched live from OpenAlex

Introduction. Combined drugs have the greatest efficacy and safety in arterial hypertension treatment. The combination of candesartan and hydrochlorothiazide (AT1-receptor antagonist and a thiazide diuretic, respectively) provides high efficiency of antihypertensive combination therapy, therefore it is widely used in medical practice. Developing a method for simultaneous determination of candesartan and hydrochlorithiazide in human blood plasma is necessary for performing the analytical part of pharmacokinetic studies and bioequivalence studies of multicomponent drugs. Aim. The aim of this study is to develop a method for quantitative determination of candesartan and hydrochlorothiazide in human plasma by high-performance liquid chromatography – tandem mass spectrometry (HPLC-MS/MS) for further bioequivalence studies. Materials and methods . Determination of candesartan and hydrochlorothiazide in human plasma by HPLC-MS/MS. The samples were processed by acetonitrile protein precipitation. Internal standard: mixed solution of valsartan and indapamide. Mobile phase: 0.1 % formic acid solution in water (eluent A), 0.1 % formic acid in acetonitrile (eluent B). Column: Phenomenex Luna Phenyl-Hexyl, 50x4.6 mm, 5 μm. Analytical range: 2.00– 300.00 ng/mL for candesartan, 2.00–200.00 ng/mL for hydrochlorothiazide in human plasma. Ionization source: electrospray ionization. Detection conditions: 441.10 → 192.00 m/z, 441.10 → 263.15 m/z (candesartan), 295.85 → 269.00 m/z (hydrochlorothiazide), 436.00 → 207.05 m/z (valsartan), 363.85 → 132.10, 363.85 → 189.00 m/z (indapamide). Results and discussion . This method was validated by selectivity, matrix effect, calibration curve, accuracy, precision, spike recovery, the lower limit of quantification, carry-over effect and stability. The developed method meets the requirements for conducting bioequivalence studies of medicinal products within the framework of the Eurasian Economic Union. Conclusion. The analytical range was 2.00–300.00 ng/mL for candesartan, 2.00–200.00 ng/mL for hydrochlorothiazide in human plasma. The method was applied in BE study of the combination of candesartan and hydrochlorothiazide.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.324
Teacher spread0.302 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueDrug development & registrationSame topicAnalytical Methods in PharmaceuticalsFrench-language works237,207