MétaCan
Menu
← Back to cohort
Record W3217380761 · doi:10.1101/2021.11.29.469919

Increased Brain Volumetric Measurement Precision from Multi-Site 3D T1-weighted 3T Magnetic Resonance Imaging by Correcting Geometric Distortions

2021· preprint· en· W3217380761 on OpenAlexafffund
Nuwan D. Nanayakkara, Stephen R. Arnott, Christopher J.M. Scott, Igor Solovey, Shuai Liang, Vladimir Fonov, Tom Gee, Dana N Broberg, Seyyed Mohammad Hassan Haddad, Joel Ramirez, Courtney Berezuk, Melissa F. Holmes, Sabrina Adamo, Miracle Ozzoude, Athena Theyers, Sujeevini Sujanthan, Mojdeh Zamyadi, Leanne K. Casaubon, Dar Dowlatshahi, Jennifer Mandzia, Demetrios J. Sahlas, Gustavo Saposnik, Ayman Hassan, Richard H. Swartz, Stephen C. Strother, Gregory M. Szilagyi, Sandra E. Black, Sean Symons

Bibliographic record

VenuebioRxiv (Cold Spring Harbor Laboratory) · 2021
Typepreprint
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsMcMaster UniversityOttawa HospitalMcGill UniversityUniversity of TorontoMontreal Neurological Institute and HospitalThunder Bay Regional Research InstituteBaycrest HospitalSunnybrook Health Science CentreWestern University
FundersGovernment of OntarioOntario Brain Institute
KeywordsScannerImaging phantomIsocenterDistortion (music)Magnetic resonance imagingStandard deviationPhysicsNuclear medicineMathematicsComputer scienceArtificial intelligenceMedicineStatisticsRadiology

Abstract

fetched live from OpenAlex

Magnetic resonance imaging (MRI) scanner-specific geometric distortions may contribute to scanner induced variability and decrease volumetric measurement precision for multi-site studies. The purpose of this study was to determine whether geometric distortion correction increases the precision of brain volumetric measurements in a multi-site multi-scanner study. Geometric distortion variation was quantified over a one-year period at 10 sites using the distortion fields estimated from monthly 3D T1-weighted MRI geometrical phantom scans. The variability of volume and distance measurements were quantified using synthetic volumes and a standard quantitative MRI (qMRI) phantom. The effects of geometric distortion corrections on MRI derived volumetric measurements of the human brain were assessed in two subjects scanned on each of the 10 MRI scanners and in 150 subjects with cerebrovascaular disease (CVD) acquired across imaging sites. Geometric distortions were found to vary substantially between different MRI scanners but were relatively stable on each scanner over a one-year interval. Geometric distortions varied spatially, increasing in severity with distance from the magnet isocenter. In measurements made with the qMRI phantom, the geometric distortion correction decreased the standard deviation of volumetric assessments by 35% and distance measurements by 42%. The average coefficient of variance decreased by 16% in gray matter and white matter volume estimates in the two subjects scanned on the 10 MRI scanners. Geometric distortion correction using an up-to-date correction field is recommended to increase precision in volumetric measurements made from MRI images.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.009
metaresearch head score (Gemma)0.029
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.009
Threshold uncertainty score0.050

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0090.029
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.250
Teacher spread0.232 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2021
Admission routes2
Has abstractyes

Explore more

Same venuebioRxiv (Cold Spring Harbor Laboratory)→Same topicAdvanced MRI Techniques and Applications→French-language works237,207→