C1 Posterior Arch Crossing Screw Fixation for Atlantoaxial Joint Instability
Bibliographic record
Abstract
STUDY DESIGN: Anatomical measurements and in vitro biomechanical testing were performed to evaluate a new method for posterior C1 fixation. OBJECTIVE: This study sought to assess C1 posterior arch crossing screw fixation for posterior C1-C2 fixation, using anatomical measurements and biomechanical testing with traditional C1 pedicle screws (PS) in a cadaveric model. SUMMARY OF BACKGROUND DATA: Atlantoaxial instability often requires surgery, and the current methods for atlas fixation incur some risk to the vascular and neurological tissues. Thus, new, effective, and safe methods are needed for salvage operations. METHODS: Morphometric analysis of the C1 posterior arch was performed using 3-dimensional computed tomography. Six fresh ligamentous human cervical spines (C0-C4) were evaluated for their biomechanics. The specimens were tested in their intact condition and after stabilization (C1-C2 PS, C1 posterior arch screws [PAS] with C2 PS) and injury due to 1.5 N·m of pure moment in flexion, extension, lateral bending, and axial rotation. During testing, 3-dimensional angular motion was measured with a motion capture platform (Vicon Nexus). Data for all scenarios were recorded, and statistical analysis was performed. RESULTS: Anatomical assessment indicated that 91.51% of C1 posterior tubercles exceeded 7 mm in thickness, 93.40% had a width of the posterior arch of greater than 3.5 mm, and 65.57% had a unilateral screw length of greater than 15 mm, indicating that the posterior arch fixation could be achieved by two 3.5 × 15-mm screws placed in a crossed manner. Twenty-two cases (11%) were not suitable for crossing screw placement because the posterior arch was flat and the entry point was present on the same side. Biomechanical testing showed that the PS and PAS rod-screw systems significantly reduced flexibility in flexion, extension, and rotation compared with the intact position. For lateral bending, there was a trend for the C1 PS and PAS systems toward decreased flexibility in comparison with the intact position. At the same time, C1 PAS decreased C1-C2 movement by 33.0% in left bending (P = 0.171) and 24.4% in right bending (P = 0.095); however, no significant difference was observed for left bending with C1 PAS compared with C1 PS, and the C1 PS and PAS systems significantly reduced the flexibility more than destabilization. CONCLUSION: Crossing screw fixation of the C1 posterior arch is straightforward and imposes little risk of injury to the neural and vascular structures as long as the implants remain intraosseous. According to the results of our anatomical and biomechanical study, C1 posterior arch crossing screw fixation may constitute an alternative method for posterior atlantoaxial fixation. LEVEL OF EVIDENCE: 3.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".