MétaCan
Menu
← Back to cohort

Abstract 19973: Dynamic Thallium-201 SPECT/CT Provides Quantitative Index of Myocardial Flow and Viability: Validation in Porcine Post-Myocardial Infarction Model

2014· article· en· W408958722 on OpenAlexaff
Stephanie Thorn, Mitchel R. Stacy, Alda Bregasi, Jin Chul Paeng, Vahid Tavakoli, James O Winters, Chris Hawley, Yang-feng TANG, James Bennett, R. Glenn Wells, Chi Liu, Ran Klein, Albert J. Sinusas

Bibliographic record

VenueCirculation · 2014
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsUniversity of Ottawa
Fundersnot available
KeywordsMedicineNuclear medicineThalliumVentriclePerfusionMyocardial infarctionGated SPECTCardiologyEjection fractionHeart failure

Abstract

fetched live from OpenAlex

Introduction: Thallium-201 (Tl-201) SPECT imaging is routinely used to evaluate relative myocardial perfusion and/or viability. In this study, we have evaluated Tl-201 kinetics in a porcine model of myocardial infarction (MI) with dynamic imaging on a hybrid SPECT/CT system. Methods: Tl-201 SPECT and contrast CT imaging were performed on hybrid SPECT/64-slice CT (GE Discovery NM/CT 570c) in Yorkshire pigs (n=5) one week following a 90 min balloon occlusion of the LAD below the first diagonal branch. Tl-201 (83-158 MBq) was injected after the initiation of a 900s list-mode acquisition. The list-mode data was reconstructed with MLEM using 30 iterations creating 23 frames (12 x 10s; 6 x 30s; 5 x 120s). Reconstructed dynamic SPECT data was analyzed using FlowquantTM semi-automated analysis software with a 1-compartment model. K1 (index of flow) and k2 (index of viability) were assessed within a 17-segment model of the left ventricle. Four segments within the central infarcted LAD territory were compared to six segments of the contralateral inferolateral wall. The same segments were analyzed for wall thickening from ECG-gated contrast CT scans using centerline approach (GE AW Cardiac Function Xpress). Results: K1 was significantly decreased in the MI vs contralateral normal regions (0.52 ± 0.17 vs 0.61 ± 0.16 ml/min/g, p<0.02). K2 an index of tissue viability was significantly increased in the MI region (0.42 ± 0.19 vs 0.32 ± 0.12 /min, p<0.04), reflecting accelerated Tl-201 washout in MI. Wall thickening in the same MI region was significantly decreased (0.33 ± 1.5 mm vs 3.3 ± 1.9 mm, p<0.005). Conclusions: Dynamic Tl-201 SPECT/CT imaging provides a quantitative index of both myocardial flow and viability using a 1-compartment model. This preliminary pre-clinical demonstrates the potential for dynamic Tl-201 SPECT imaging to quantify myocardial viability early post-MI.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.276
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueCirculation→Same topicCardiac Imaging and Diagnostics→French-language works237,207→