MétaCan
Menu
Back to cohort

A field study on summertime overheating of six schools in Montreal Canada

2021· article· en· W4200042638 on OpenAlexafffundabout
Zihan Xie, Chang Shu, Ben Zegen Reich, Lin Wang, Daniel Baril, Lili Ji, Senwen Yang, Xuechen Bai, Radu Zmeureanu, Michael Lacasse, Liangzhu Wang, Hua Ge

Bibliographic record

VenueJournal of Physics Conference Series · 2021
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsNational Research Council CanadaConcordia University
FundersNatural Sciences and Engineering Research Council of CanadaMinistère de la Santé et des Services sociaux
KeywordsOverheating (electricity)Environmental scienceMeteorologyWet-bulb globe temperatureRelative humidityWind speedThermal comfortHumidityAtmospheric sciencesGeographyEngineering

Abstract

fetched live from OpenAlex

Abstract Due to global climate change, the world has been experiencing significant increases in average temperatures and the frequency and intensity of extreme weather events such as heatwaves. The overheating problem in indoor spaces of buildings has become a concern to the comfort and health of building occupants, especially vulnerable populations such as the elderly, children, or the sick. A field monitoring network consisting of rooftop weather stations and indoor sensors has been set up on 11 buildings of different types in Montreal, Canada. This paper presents the results of field measurements of indoor thermal conditions of six school buildings to assess the risks of summertime overheating. These six primary school buildings were built in 1930-1966 with window-wall-ratios between 10-30% and limited mechanical ventilation. The indoor dry-bulb air temperature, relative humidity, and CO 2 concentrations are measured by indoor wireless sensors. The weather conditions, including dry-bulb temperature, relative humidity, solar radiation, rainfall, wind speed, and wind direction, are measured by rooftop weather stations. Measurements presented in this paper are collected from July to September 2020, which include four different time intervals: (a) during two heatwaves, (b) during summer break when schools were closed, and (c) when schools were reopened, and windows were intermittently opened. Data analysis shows that the indoor and outdoor temperature difference has a strong linear correlation with the outdoor temperature observed for all school buildings. This correlation is also affected by building operations, such as opening windows, closing blinds, and the micro-climate of their surroundings.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.913
Threshold uncertainty score0.994

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.210
Teacher spread0.199 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2021
Admission routes3
Has abstractyes

Explore more

Same venueJournal of Physics Conference SeriesSame topicBuilding Energy and Comfort OptimizationFrench-language works237,207