MétaCan
Menu
Back to cohort

Improving thermal comfort conditions in K-12 educational buildings in hot and humid climate: a case study in Cucuta, Colombia

2021· article· en· W4200068098 on OpenAlexaff
David Guerrero, Hui-Bin Ge, B Lee

Bibliographic record

VenueJournal of Physics Conference Series · 2021
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsCollège de Maisonneuve
Fundersnot available
KeywordsASHRAE 90.1Thermal comfortNatural ventilationOccupancyEnvironmental scienceRoofArchitectural engineeringVentilation (architecture)Relative humidityMeteorologyCivil engineeringEngineeringGeography

Abstract

fetched live from OpenAlex

Abstract The school buildings in Colombia are built based on geographical locations and regional construction systems. However, external weather conditions and building design can have a significant impact on the thermal comfort of students, which affects the academic performance and productivity. This paper investigates the thermal comfort performance for an educational building in a hot and humid city in Cucuta, Colombia, built under national guidelines. This school is a concrete structure without mechanical cooling. However, field observation discovered that 82% of the time students experienced thermal discomfort. To investigate causes and provide mitigation strategies, a whole building energy simulation is conducted. Design Builder is used to evaluate the indoor thermal conditions compared to outdoor data collected. ASHRAE 55 adaptative model is used for the evaluation. It is found that 79% of the time the thermal conditions are outside the acceptable range during the year. The effect of mitigation measures i.e., occupancy, roof insulation, and natural ventilation rates are investigated through simulations. It is found that occupancy and natural ventilation rate have a significant impact on the indoor temperature and relative humidity, and thus the thermal comfort. Passive design strategies are proposed in optimizing the school building design to meet ASHARE-55 requirements.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.233
Threshold uncertainty score0.464

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0010.001
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.244
Teacher spread0.231 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Physics Conference SeriesSame topicBuilding Energy and Comfort OptimizationFrench-language works237,207