MétaCan
Menu
Back to cohort
Record W4200105313 · doi:10.1089/ast.2021.0110

Science and Curation Considerations for the Design of a Mars Sample Return (MSR) Sample Receiving Facility (SRF)

2021· article· en· W4200105313 on OpenAlexaff
Brandi L. Carrier, David Beaty, Aurore Hützler, Alvin L. Smith, Gerhard Kminek, Michael A. Meyer, T. Haltigin, L. E. Hays, C. B. Agee, H. Busemann, Barbara Cavalazzi, Charles S. Cockell, Vinciane Debaille, D. P. Glavin, M. M. Grady, Ernst Hauber, Bernard Marty, F. M. McCubbin, Lisa M. Pratt, A. B. Regberg, Caroline L. Smith, Roger E. Summons, T. D. Swindle, K. T. Tait, Nicholas J. Tosca, Arya Udry, Tomohiro Usui, M. A. Velbel, M. Wadhwa, Francès Westall, María‐Paz Zorzano

Bibliographic record

VenueAstrobiology · 2021
Typearticle
Languageen
FieldPhysics and Astronomy
TopicPlanetary Science and Exploration
Canadian institutionsRoyal Ontario MuseumCanadian Space Agency
FundersCollege of Engineering, Michigan State UniversityNational Aeronautics and Space AdministrationEuropean Space AgencyMinisterio de Ciencia e InnovaciónMichigan State UniversitySchweizerischer Nationalfonds zur Förderung der Wissenschaftlichen ForschungNational Science Foundation
KeywordsSample (material)Mars Exploration ProgramComputer scienceProtocol (science)Sample size determinationStatisticsPhysicsMedicineMathematicsAstrobiology

Abstract

fetched live from OpenAlex

The most important single element of the “ground system” portion of a Mars Sample Return (MSR) Campaign is a facility referred to as the Sample Receiving Facility (SRF), which would need to be designed and equipped to receive the returned spacecraft, extract and open the sealed sample container, extract the samples from the sample tubes, and implement a set of evaluations and analyses of the samples. One of the main findings of the first MSR Sample Planning Group (MSPG, 2019a) states that “The scientific community, for reasons of scientific quality, cost, and timeliness, strongly prefers that as many sample-related investigations as possible be performed in PI-led laboratories outside containment.” There are many scientific and technical reasons for this preference, including the ability to utilize advanced and customized instrumentation that may be difficult to reproduce inside in a biocontained facility, and the ability to allow multiple science investigators in different labs to perform similar or complementary analyses to confirm the reproducibility and accuracy of results. It is also reasonable to assume that there will be a desire for the SRF to be as efficient and economical as possible, while still enabling the objectives of MSR to be achieved. For these reasons, MSPG concluded, and MSPG2 agrees, that the SRF should be designed to accommodate only those analytical activities that could not reasonably be done in outside laboratories because they are time- or sterilization-sensitive, are necessary for the Sample Safety Assessment Protocol (SSAP), or are necessary parts of the initial sample characterization process that would allow subsamples to be effectively allocated for investigation. All of this must be accommodated in an SRF, while preserving the scientific value of the samples through maintenance of strict environmental and contamination control standards. Executive Summary The most important single element of the “ground system” portion of a Mars Sample Return (MSR) Campaign is a facility referred to as the Sample Receiving Facility (SRF), which would need to be designed and equipped to enable receipt of the returned spacecraft, extraction and opening of the sealed sample container, extraction of the samples from the sample tubes, and a set of evaluations and analyses of the samples—all under strict protocols of biocontainment and contamination control. Some of the important constraints in the areas of cost and required performance have not yet been set by the necessary governmental sponsors, but it is reasonable to assume there will be a desire for the SRF to be as efficient and economical as is possible, while still enabling the objectives of MSR science to be achieved. Additionally, one of the main findings of MSR Sample Planning Group (MSPG, 2019a) states “The scientific community, for reasons of scientific quality, cost, and timeliness, strongly prefers that as many sample-related investigations as possible be performed in PI-led laboratories outside containment.” There are many scientific and technical reasons for this preference, including the ability to utilize advanced and customized instrumentation that may be difficult to reproduce inside a biocontained facility. Another benefit is the ability to enable similar or complementary analyses by multiple science investigators in different laboratories, which would confirm the reproducibility and accuracy of results. For these reasons, the MSPG concluded—and the MSR Science Planning Group Phase 2 (MSPG2) agrees—that the SRF should be designed to accommodate only those analytical activities inside biocontainment that could not reasonably be done in outside laboratories because such activities are time-sensitive, sterilization-sensitive, required by the Sample Safety Assessment Protocol (SSAP), or are necessary parts of the initial sample characterization process that would allow subsamples to be effectively allocated for investigation. All activities within the SRF must be done while preserving the scientific value of the samples through maintenance of strict environmental and contamination control standards. The SRF would need to provide a unique environment that consists of both Biosafety Level 4 (BSL-4) equivalent containment and a very high level of contamination control. The SRF would also need to accommodate the following activities: Receipt of the returned spacecraft, presumably in a sealed shipping container De-integration ( i.e., disassembly) and assessment of the returned system, beginning with the spacecraft exterior and ending with accessing and isolating all Mars material (gas, dust, regolith, and rock) Initial sample characterization, leading to development of a sample catalog sufficient to support sample allocation (see Tait et al., 2022 ) Science investigations necessary to complete the SSAP (see Kminek et al., 2021) Certain science investigations that are both time- and sterilization-sensitive (see Tosca et al., 2022 ; Velbel et al., 2022 ) A managed transition to post-SRF activities that would include analysis of samples (either sterilized or not) outside biocontainment and the transfer of some or all samples to one or more uncontained curation facilities The MSPG2 has produced a compilation of potential design requirements for the SRF, based on the list of activities noted above, that can be used in cost and schedule planning. The text of this report is meant to serve as an overview and explanation of these proposed SRF Design Requirements that have been compiled by the MSPG2 SRF Requirements Focus Group (Supplement 1). Summary of Findings FINDING SRF-1: The quality of the science that can be achieved with the MSR samples will be negatively impacted if they are not protected from contamination and inappropriate environmental conditions. A significant amount of SRF infrastructure would therefore be necessary to maintain and monitor appropriate levels of cleanliness, contamination control, and environmental conditions. FINDING SRF-2: Although most MSR sample investigations would take place outside of the SRF, the SRF needs to include significant laboratory capabilities with advanced instruments and associated sample preparation systems to enable the MSR science objectives to be successfully achieved. FINDING SRF-3: Preliminary studies of different operational scenarios should be started as soon as possible to enable analysis of the trade-offs between the cost and size of the SRF and the amount of time needed to prepare the samples for allocation and analysis. FINDING SRF-4: The ability to add additional analytical capabilities within biocontainment should be preserved to address the contingency scenario in which unsterilized material is not cleared to be analyzed outside of biocontainment. If potential evidence of martian life were to be detected in the samples, for example, it would be a high priority to conduct further investigations related to any putative lifeforms, as well as to enable other sterilization-sensitive science investigations to be conducted in biocontainment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.810
Threshold uncertainty score0.257

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.058
GPT teacher head0.265
Teacher spread0.207 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueAstrobiologySame topicPlanetary Science and ExplorationFrench-language works237,207