Impedance Monitoring for Nerve Regeneration Using an Implantable Cuff
Bibliographic record
Abstract
A miniaturized discrete system to measure impedance for long term monitoring of peripheral nerve regeneration after injury, has been developed in this work. The device uses programmable sinusoidal currents that are injected into tissue and resulting potentials developed are measured to calculate the impedance of the nerve. It features a single current source and two single pole triple throw switches for measuring between any pair of 4 electrodes. In addition, a procedure for developing a polydimethylsiloxane (PDMS) cuff to embed platinum ring electrodes and eventually electronics is also presented. Devices were tested in saline solutions, acute experiments with in vivo and resected nerves, and in a 3-week in vivo implant experiment in rats. Developing a novel method to monitor nerve regeneration while reducing the number of surgeries is a desirable way to improve and track outcomes of repair and rehabilitation of injured nerves.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".