MétaCan
Menu
Back to cohort

2D Ultrasound Validation to Assess the Accuracy of Hip Displacement Measurement: A Phantom Study

2021· article· en· W4200486291 on OpenAlexafffund
Thanh-Tu Pham, Thanh‐Giang La, Lawrence H. Le, John Andersen, Edmond Lou

Bibliographic record

Venue2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · 2021
Typearticle
Languageen
FieldMedicine
TopicHip disorders and treatments
Canadian institutionsUniversity of Alberta
FundersGlenrose Rehabilitation Hospital
KeywordsImaging phantomAcetabulumCerebral palsyMedicineUltrasoundDisplacement (psychology)Gold standard (test)RadiographyNuclear medicineIonizing radiationOrthopedic surgeryFemoral headRadiologySurgeryIrradiationPhysical medicine and rehabilitationPhysics

Abstract

fetched live from OpenAlex

Hip displacement is a common orthopedic abnormality in children with cerebral palsy and is assessed on anteroposterior pelvic radiographs during surveillance. Repeated exposure to ionizing radiation is a major concern of cancer risks for children. Ultrasound (US) has been proposed to image the hips. The severity of hip displacement is measured by the Reimers' migration percentage (MP), which is calculated by the ratio of the femoral head distance from the acetabulum to the width of the femoral head. Methods have been published to estimate MP from the US hip images in literature; however, validation for accuracy has not been reported. This study aimed to determine the accuracy of the 2D ultrasound techniques using two 3D printed hip phantoms with known MP values. The MPs estimated from the US images were compared with those measured from the X-ray images. Based on the experimental results, the US measurements had a maximum absolute discrepancy of 2.2% as compared to 9.8% from the X-ray measurements for the MP. The study on phantoms has showed the proposed US approach is promising with better accuracy and without ionizing radiation.Clinical Relevance - If the accuracy is proved to be at least as good as the current X-ray gold standard, the proposed US method will provide a modality of choice to pediatric patients for hip displacement diagnostics and hip surveillance, especially those with cerebral palsy. The method will be free of ionizing radiation and therefore significantly improve the pediatric patient care.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.011
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.011
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.109
GPT teacher head0.371
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2021
Admission routes2
Has abstractyes

Explore more

Same venue2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)Same topicHip disorders and treatmentsFrench-language works237,207