MétaCan
Menu
Back to cohort
Record W4200579465 · doi:10.1002/mrm.29129

Hadamard‐encoded dual‐voxel SPECIAL: Short‐TE MRS acquired in two brain regions simultaneously using Hadamard encoding

2021· article· en· W4200579465 on OpenAlexafffund
Masoumeh Dehghani, Richard A.E. Edden, Jamie Near

Bibliographic record

VenueMagnetic Resonance in Medicine · 2021
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity of TorontoMcGill UniversityDouglas Mental Health University InstituteSunnybrook Health Science Centre
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health Research
KeywordsHadamard transformVoxelSubtractionImaging phantomScannerNuclear magnetic resonancePulse sequencePhysicsComputer scienceSpin echoAlgorithmMathematicsArtificial intelligenceOpticsMagnetic resonance imagingArithmetic

Abstract

fetched live from OpenAlex

PURPOSE: The spin-echo, full-intensity acquired localized (SPECIAL) sequence is a method for single-voxel, localized MRS in vivo with short TEs. In this study we modified the SPECIAL sequence to simultaneously record spectra from two volumes of interest. This new technique is called Hadamard-encoded dual-voxel SPECIAL (HD-SPECIAL). METHODS: The SPECIAL sequence consists of a spin echo localized to a column of tissue, preceded by a slice-selective inversion pulse in alternating scans to invert a section of the column. Full localization is achieved by subtraction of the inversion-on scans from the inversion-off scans. In HD-SPECIAL, the two-step inversion scheme is replaced by a four-step Hadamard-encoded scheme involving single-band and dual-band inversion pulses to select two regions of the spin-echo column. By appropriate Hadamard combination of the four acquired shots, spectra can be reconstructed from both desired regions. This approach does not rely on parallel imaging reconstruction. Using a 3T scanner, HD-SPECIAL localization is demonstrated both in phantoms and in the human brain in vivo, and the performance of HD-SPECIAL is assessed by comparing with the conventional SPECIAL sequence. RESULTS: Phantom and in vivo measurements show excellent agreement between measures from HD-SPECIAL and SPECIAL sequences. Relative to consecutive SPECIAL measurements from two regions, HD-SPECIAL reduces the total scan time 2-fold with minimal penalty in terms of spectral quality or SNR. CONCLUSION: The HD-SPECIAL sequence enables reliable acquisition of MR spectra simultaneously from two regions at 3 T, offering the potential to study interregional variations in metabolite concentrations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.045
GPT teacher head0.366
Teacher spread0.321 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207