MétaCan
Menu
Back to cohort
Record W4205135292 · doi:10.1364/josab.446625

Characteristics of a rectangular channel sensor based on evanescent field enhanced photonic crystal fiber

2022· article· en· W4205135292 on OpenAlexaff
Tao Shen, Liang Han, Xin Liu, Yue Feng, Tao Xu, Chi Liu, Wei Han

Bibliographic record

VenueJournal of the Optical Society of America B · 2022
Typearticle
Languageen
FieldEngineering
TopicPhotonic Crystal and Fiber Optics
Canadian institutionsMinistry of Education and Child Care
FundersFundamental Research Funds for the Central UniversitiesNational Natural Science Foundation of China
KeywordsPhotonic-crystal fiberPhotonic crystalEvanescent waveChannel (broadcasting)FiberField (mathematics)Materials scienceOptoelectronicsMicrostructured optical fiberOpticsFiber optic sensorPolarization-maintaining optical fiberTelecommunicationsPhysicsEngineeringComposite materialMathematics

Abstract

fetched live from OpenAlex

A miniaturized, rectangular-channel photonic crystal fiber (RC-PCF) high-sensitivity sensing scheme is proposed for high-refractive-index liquid analysis. The designed PCF is polished and features an open rectangular channel in the upper-middle part of the fiber cross-section, which facilitates the efficient flow of the sample liquid. The design utilizes the merit of photonic crystal array and the operability of external sensing. Gold is chosen as the plasma material because of its chemical stability and biocompatibility in a liquid environment. To obtain high sensitivity, the effect of the sample liquid height in the channel on the sensing performance is investigated. Numerical results show that the maximum wavelength sensitivity and amplitude sensitivity of the sensor is 28,000 nm/RIU (refractive index unit) and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mo>−</mml:mo> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mn>1266.5</mml:mn> </mml:mrow> <mml:mspace width="thickmathspace"/> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">R</mml:mi> <mml:mi mathvariant="normal">I</mml:mi> </mml:mrow> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msup> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">U</mml:mi> </mml:mrow> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mo>−</mml:mo> <mml:mn>1</mml:mn> </mml:mrow> </mml:msup> </mml:mrow> </mml:math> with a liquid analyte height of 100% of the channel height. The maximum wavelength sensitivity increases from 28,000 to 42,000 nm/RIU when the gold film thickness decreases from 30 nm to 20 nm. Due to the sensor’s simple structure and high sensitivity, it will have potential applications in the detection of high-refractive-index samples in biology, medicine, and chemistry.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.463
Threshold uncertainty score0.435

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.200
Teacher spread0.195 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of the Optical Society of America BSame topicPhotonic Crystal and Fiber OpticsFrench-language works237,207