MétaCan
Menu
Back to cohort
Record W4205192005 · doi:10.2196/30791

Accuracy and Acceptability of Wrist-Wearable Activity-Tracking Devices: Systematic Review of the Literature

2021· review· en· W4205192005 on OpenAlexaff
Federico Germini, Noella Noronha, Victoria Borg Debono, Binu A. Philip, Drashti Pete, Tamara Navarro, Arun Keepanasseril, Sameer Parpia, Kerstin de Wit, Alfonso Iorio

Bibliographic record

VenueJournal of Medical Internet Research · 2021
Typereview
Languageen
FieldMedicine
TopicPhysical Activity and Health
Canadian institutionsMcMaster UniversityQueen's UniversityImpact
Fundersnot available
KeywordsWearable computerWearable technologyTracking (education)Computer sciencePhysical medicine and rehabilitationWristMedicineHuman–computer interactionApplied psychologyPsychologySurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Numerous wrist-wearable devices to measure physical activity are currently available, but there is a need to unify the evidence on how they compare in terms of acceptability and accuracy. OBJECTIVE: The aim of this study is to perform a systematic review of the literature to assess the accuracy and acceptability (willingness to use the device for the task it is designed to support) of wrist-wearable activity trackers. METHODS: We searched MEDLINE, Embase, the Cochrane Central Register of Controlled Trials, and SPORTDiscus for studies measuring physical activity in the general population using wrist-wearable activity trackers. We screened articles for inclusion and, for the included studies, reported data on the studies' setting and population, outcome measured, and risk of bias. RESULTS: A total of 65 articles were included in our review. Accuracy was assessed for 14 different outcomes, which can be classified in the following categories: count of specific activities (including step counts), time spent being active, intensity of physical activity (including energy expenditure), heart rate, distance, and speed. Substantial clinical heterogeneity did not allow us to perform a meta-analysis of the results. The outcomes assessed most frequently were step counts, heart rate, and energy expenditure. For step counts, the Fitbit Charge (or the Fitbit Charge HR) had a mean absolute percentage error (MAPE) <25% across 20 studies. For heart rate, the Apple Watch had a MAPE <10% in 2 studies. For energy expenditure, the MAPE was >30% for all the brands, showing poor accuracy across devices. Acceptability was most frequently measured through data availability and wearing time. Data availability was ≥75% for the Fitbit Charge HR, Fitbit Flex 2, and Garmin Vivofit. The wearing time was 89% for both the GENEActiv and Nike FuelBand. CONCLUSIONS: The Fitbit Charge and Fitbit Charge HR were consistently shown to have a good accuracy for step counts and the Apple Watch for measuring heart rate. None of the tested devices proved to be accurate in measuring energy expenditure. Efforts should be made to reduce the heterogeneity among studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.061
metaresearch head score (Gemma)0.285
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.061
Threshold uncertainty score0.324

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0610.285
Meta-epidemiology (narrow)0.0020.002
Meta-epidemiology (broad)0.0110.013
Bibliometrics0.0160.014
Science and technology studies0.0010.002
Scholarly communication0.0050.005
Open science0.0030.003
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.191
GPT teacher head0.530
Teacher spread0.339 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations212
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Medical Internet ResearchSame topicPhysical Activity and HealthFrench-language works237,207