MétaCan
Menu
Back to cohort
Record W4205716904 · doi:10.1002/rcm.9244

Rapid screening procedures for a variety of complex forensic samples using laser diode thermal desorption (LDTD) coupled to different mass spectrometers

2022· article· en· W4205716904 on OpenAlexaff
Eshwar Jagerdeo, Serge Auger

Bibliographic record

VenueRapid Communications in Mass Spectrometry · 2022
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsPhytronix (Canada)
Fundersnot available
KeywordsChemistryMass spectrometryAnalytical Chemistry (journal)Thermal desorptionSpectrometerMass spectrumExplosive materialChemical ionizationChromatographyIonizationDesorptionIonOptics

Abstract

fetched live from OpenAlex

RATIONALE: The applications shared in this paper demonstrate the wide variety of samples that can be analyzed when Laser Diode Thermal Desorption (LDTD) is interfaced with a high-resolution mass spectrometer and show the speed at which high quality data can be generated from complex matrices. METHODS: Samples are solvent extracted and spotted in a 96-well plate. In the case of biological fluids, hydrolysis followed by solid-phase extraction is required. The solvent in the 96-well plate is evaporated followed by mass spectrometric (MS) analysis with atmospheric pressure chemical ionization. Where applicable, the instrument is operated in data-dependent mode, with a full-scan mass spectrum followed by MS/MS spectra of the top 10 ions with a total runtime of 0.4 min. RESULTS: Four applications (MAAQ and Tear Gas, twelve rodenticides, seven explosives, and 40 drugs of abuse) are reported in this paper. MAAQ, tear gas, and rodenticides were identified by full-scan, followed by MS/MS experiments at levels of 125 μg/L, 125 μg/L, and 500 μg/L, respectively. Explosives were all identified at 102 μg/L by full-scan experiments. The drugs of abuse were identified by multiple reaction monitoring (MRM) experiments at defined cutoff levels from 2 to 1000 μg/L. CONCLUSIONS: Interfacing LDTD with a mass spectrometer allows for rapid screening of a wide range of samples, with either minimal or complex sample preparation. Using a high-resolution mass spectrometer with the combination to perform full-scan and MS/MS experiments adds a high level of specificity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.003
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.068
GPT teacher head0.307
Teacher spread0.239 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueRapid Communications in Mass SpectrometrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207