MétaCan
Menu
Back to cohort
Record W4205921047 · doi:10.1002/jmri.28056

Modifying <scp>LI‐RADS</scp> on Gadoxetate Disodium‐Enhanced <scp>MRI</scp>: A Secondary Analysis of a Prospective Observational Study

2022· article· en· W4205921047 on OpenAlexaff
Hanyu Jiang, Bin Song, Yun Qin, Meghana Konanur, Yuanan Wu, Matthew D. F. McInnes, Kyle J. Lafata, Mustafa R. Bashir

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2022
Typearticle
Languageen
FieldMedicine
TopicHepatocellular Carcinoma Treatment and Prognosis
Canadian institutionsOttawa HospitalUniversity of Ottawa
FundersNational Natural Science Foundation of China
KeywordsMedicineInterquartile rangeMcNemar's testNuclear medicineDiffusion MRIProspective cohort studyRadiologyMagnetic resonance imagingHepatocellular carcinomaReceiver operating characteristicPathologyInternal medicineMathematics

Abstract

fetched live from OpenAlex

BACKGROUND: The Liver Imaging Reporting and Data System (LI-RADS) is widely used for diagnosing hepatocellular carcinoma (HCC), however, with unsatisfactory sensitivity, complex ancillary features, and inadequate integration with gadoxetate disodium (EOB)-enhanced MRI. PURPOSE: To modify LI-RADS (mLI-RADS) on EOB-MRI. STUDY TYPE: Secondary analysis of a prospective observational study. POPULATION: Between July 2015 and September 2018, 224 consecutive high-risk patients (median age, 51 years; range, 26-83; 180 men; training/testing sets: 169/55 patients) with 742 (median size, 13 mm; interquartile range, 7-27; 498 HCCs) LR-3/4/5 observations. FIELD STRENGTH/SEQUENCE: -weighted gradient echo sequences. ASSESSMENT: Three radiologists (with 5, 5, and 10 years of experience in liver MR imaging, respectively) blinded to the reference standard (histopathology or imaging follow-up) reviewed all MR images independently. In the training set, the optimal LI-RADS version 2018 (v2018) features selected by Random Forest analysis were used to develop mLI-RADS via decision tree analysis. STATISTICAL TESTS: In an independent testing set, diagnostic performances of mLI-RADS, LI-RADS v2018, and the Korean Liver Cancer Association (KLCA) guidelines were computed using a generalized estimating equation model and compared with McNemar's test. A two-tailed P < 0.05 was statistically significant. RESULTS: Five features (nonperipheral "washout," restricted diffusion, nonrim arterial phase hyperenhancement [APHE], mild-moderate T2 hyperintensity, and transitional phase hypointensity) constituted mLI-RADS, and mLR-5 was nonperipheral washout coupled with either nonrim APHE or restricted diffusion. In the testing set, mLI-RADS was significantly more sensitive (72%) and accurate (80%) than LI-RADS v2018 (sensitivity, 61%; accuracy 74%; both P < 0.001) and the KLCA guidelines (sensitivity, 64%; accuracy 74%; both P < 0.001), without sacrificing positive predictive value (mLI-RADS, 94%; LI-RADS v2018, 94%; KLCA guidelines, 92%). DATA CONCLUSION: In high-risk patients, the EOB-MRI-based mLI-RADS was simpler and more sensitive for HCC than LI-RADS v2018 while maintaining high positive predictive value. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.031

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.010
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.052
GPT teacher head0.280
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicHepatocellular Carcinoma Treatment and PrognosisFrench-language works237,207