MétaCan
Menu
Back to cohort
Record W4205961587 · doi:10.1177/21925682211068419

The Influence of Regional Differences on the Reliability of the AO Spine Sacral Injury Classification System

2022· article· en· W4205961587 on OpenAlexaff
Brian A. Karamian, Gregory D. Schroeder, Mark J. Lambrechts, José A. Canseco, Emiliano Vialle, Shanmuganathan Rajasekaran, Lorin M. Benneker, Frank Kandziora, F. Cumhur Öner, Klaus John Schnake, Christopher K. Kepler, Alexander R. Vaccaro

Bibliographic record

VenueGlobal Spine Journal · 2022
Typearticle
Languageen
FieldMedicine
TopicPelvic and Acetabular Injuries
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsReproducibilityMedicineReliability (semiconductor)Latin AmericansStatistics

Abstract

fetched live from OpenAlex

Study Design Global cross-sectional survey. Objective To explore the influence of geographic region on the AO Spine Sacral Classification System. Methods A total of 158 AO Spine and AO Trauma members from 6 AO world regions (Africa, Asia, Europe, Latin and South America, Middle East, and North America) participated in a live webinar to assess the reliability, reproducibility, and accuracy of classifying sacral fractures using the AO Spine Sacral Classification System. This evaluation was performed with 26 cases presented in randomized order on 2 occasions 3 weeks apart. Results A total of 8320 case assessments were performed. All regions demonstrated excellent intraobserver reproducibility for fracture morphology. Respondents from Europe (k = .80) and North America (k = .86) achieved excellent reproducibility for fracture subtype while respondents from all other regions displayed substantial reproducibility. All regions demonstrated at minimum substantial interobserver reliability for fracture morphology and subtype. Each region demonstrated >90% accuracy in classifying fracture morphology and >80% accuracy in fracture subtype compared to the gold standard. Type C morphology (p 2 = .0000) and A3 (p 1 = .0280), B2 (p 1 = .0015), C0 (p 1 = .0085), and C2 (p 1 =.0016, p 2 =.0000) subtypes showed significant regional disparity in classification accuracy (p 1 = Assessment 1, p 2 = Assessment 2). Respondents from Asia (except in A3) and the combined group of North, Latin, and South America had accuracy percentages below the combined mean, whereas respondents from Europe consistently scored above the mean. Conclusions In a global validation study of the AO Spine Sacral Classification System, substantial reliability of both fracture morphology and subtype classification was found across all geographic regions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.029
metaresearch head score (Gemma)0.064
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.029
Threshold uncertainty score0.151

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0290.064
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.273
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueGlobal Spine JournalSame topicPelvic and Acetabular InjuriesFrench-language works237,207