MétaCan
Menu
Back to cohort
Record W4206299895 · doi:10.1002/mrm.29153

Volumetric and multispectral DWI near metallic implants using a non‐linear phase Carr‐Purcell‐Meiboom‐Gill diffusion preparation

2022· article· en· W4206299895 on OpenAlexfundno aff
Philip K. Lee, Daehyun Yoon, Jesse K. Sandberg, Shreyas Vasanawala, Brian A. Hargreaves

Bibliographic record

VenueMagnetic Resonance in Medicine · 2022
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsnot available
FundersNational Institute of Biomedical Imaging and BioengineeringNational Institute of Arthritis and Musculoskeletal and Skin DiseasesNatural Sciences and Engineering Research Council of CanadaGE HealthcareNational Institutes of Health
KeywordsImaging phantomMultispectral imageBandwidth (computing)Phase (matter)Magnetic resonance imagingOpticsPulse sequenceNuclear magnetic resonanceMaterials sciencePhysicsComputer scienceRadiology

Abstract

fetched live from OpenAlex

Purpose DWI near metal implants has not been widely explored due to substantial challenges associated with through‐slice and in‐plane distortions, the increased encoding requirement of different spectral bins, and limited SNR. There is no widely adopted clinical protocol for DWI near metal since the commonly used EPI trajectory fails completely due to distortion from extreme off‐resonance ranging from 2 to 20 kHz. We present a sequence that achieves DWI near metal with moderate b‐values (400–500 s/mm2) and volumetric coverage in clinically feasible scan times. Theory and Methods Multispectral excitation with Cartesian sampling, view angle tilting, and kz phase encoding reduce in‐plane and through‐plane off‐resonance artifacts, and Carr‐Purcell‐Meiboom‐Gill (CPMG) spin‐echo refocusing trains counteract T2* effects. The effect of random phase on the refocusing train is eliminated using a stimulated echo diffusion preparation. Root‐flipped Shinnar‐Le Roux refocusing pulses permits preparation of a high spectral bandwidth, which improves imaging times by reducing the number of excitations required to cover the desired spectral range. B1 sensitivity is reduced by using an excitation that satisfies the CPMG condition in the preparation. A method for ADC quantification insensitive to background gradients is presented. Results Non‐linear phase refocusing pulses reduces the peak B1 by 46% which allows RF bandwidth to be doubled. Simulations and phantom experiments show that a non‐linear phase CPMG pulse pair reduces B1 sensitivity. Application in vivo demonstrates complementary contrast to conventional multispectral acquisitions and improved visualization compared to DW‐EPI. Conclusion Volumetric and multispectral DW imaging near metal can be achieved with a 3D encoded sequence.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.362
Teacher spread0.335 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207