MétaCan
Menu
Back to cohort

Multi-contrast CT imaging using a high energy resolution CdTe detector and a CZT photon-counting detector

2022· article· en· W4206803310 on OpenAlexaff
Nathan Clements, Devon Richtsmeier, Alexander Hart, Magdalena Bazalova‐Carter

Bibliographic record

VenueJournal of Instrumentation · 2022
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsUniversity of Victoria
Fundersnot available
KeywordsCadmium zinc tellurideImaging phantomDetectorCadmium telluride photovoltaicsOpticsMaterials sciencePhysicsContrast (vision)Image resolutionPhoton countingResolution (logic)SubtractionNuclear medicineOptoelectronicsMedicineComputer scienceArtificial intelligenceMathematics

Abstract

fetched live from OpenAlex

Abstract Computed tomography (CT) imaging with high energy resolution detectors shows great promise in material decomposition and multi-contrast imaging. Multi-contrast imaging was studied by imaging a phantom with iodine (I), gadolinium (Gd), and gold (Au) solutions, and mixtures of the three using a cadmium telluride (CdTe) spectrometer with an energy resolution of 1% as well as with a cadmium zinc telluride (CZT) detector with an energy resolution of 13%. The phantom was imaged at 120 kVp and 1.1 mA with 7 mm of aluminum filtration. For the CdTe data collection, the phantom was imaged using a 0.2 mm diameter x-ray beam with 96 ten-second data acquisitions across the phantom at 45 rotation angles. For the CZT detector, we had 720 projections using a cone beam, and the six detector energy thresholds were set to 23, 33, 50, 64, 81, and 120 keV so that three thresholds corresponded to the K-edges of the contrast agents. Contrast agent isolation methods were then examined. K-edge subtraction and novel spectrometric algebraic image reconstruction (SAIR) were used for the CdTe data. K-edge subtraction alone was used for the CZT data. Linearity plots produced similar R 2 values and slopes for all three reconstruction methods. Comparing CdTe methods, SAIR offered less noise than CdTe K-edge subtraction and better geometric accuracy at low contrast concentrations. CdTe contrast agent images of I, Gd, and Au offered less noise and greater contrast than the CZT images, highlighting the benefits of high energy resolution CdTe detectors for possible use in pre-clinical or clinical CT imaging.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.223
Teacher spread0.215 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of InstrumentationSame topicAdvanced X-ray and CT ImagingFrench-language works237,207