MétaCan
Menu
Back to cohort
Record W4206987396 · doi:10.1371/journal.pmed.1003905

Ruling out pulmonary embolism across different healthcare settings: A systematic review and individual patient data meta-analysis

2022· review· en· W4206987396 on OpenAlexafffund
Geert‐Jan Geersing, Toshihiko Takada, Frederikus A. Klok, Harry R. Büller, D. Mark Courtney, Yonathan Freund, Javier Galipienzo, Grégoire Le Gal, Waleed Ghanima, Jeffrey A. Kline, Menno V. Huisman, Karel G. M. Moons, Arnaud Perrier, Sameer Parpia, Helia Robert‐Ebadi, Marc Righini, Pierre‐Marie Roy, Maarten van Smeden, Milou A.M. Stals, Philip S. Wells, Kerstin de Wit, Noémie Kraaijpoel, Nick van Es

Bibliographic record

VenuePLoS Medicine · 2022
Typereview
Languageen
FieldMedicine
TopicVenous Thromboembolism Diagnosis and Management
Canadian institutionsQueen's UniversityMcMaster UniversityImpactUniversity of OttawaWilfrid Laurier UniversityOttawa Hospital
FundersPrincipia BiopharmaSwedish Orphan BiovitrumNederlandse Organisatie voor Wetenschappelijk OnderzoekZonMwUniversity of OttawaSanofiDaiichi-SankyoAmgenPfizerBristol-Myers SquibbHeart and Stroke Foundation of Canada
KeywordsMeta-analysisMedicinePulmonary embolismHealth careSystematic reviewIntensive care medicineMEDLINEInternal medicineBiology

Abstract

fetched live from OpenAlex

BACKGROUND: The challenging clinical dilemma of detecting pulmonary embolism (PE) in suspected patients is encountered in a variety of healthcare settings. We hypothesized that the optimal diagnostic approach to detect these patients in terms of safety and efficiency depends on underlying PE prevalence, case mix, and physician experience, overall reflected by the type of setting where patients are initially assessed. The objective of this study was to assess the capability of ruling out PE by available diagnostic strategies across all possible settings. METHODS AND FINDINGS: We performed a literature search (MEDLINE) followed by an individual patient data (IPD) meta-analysis (MA; 23 studies), including patients from self-referral emergency care (n = 12,612), primary healthcare clinics (n = 3,174), referred secondary care (n = 17,052), and hospitalized or nursing home patients (n = 2,410). Multilevel logistic regression was performed to evaluate diagnostic performance of the Wells and revised Geneva rules, both using fixed and adapted D-dimer thresholds to age or pretest probability (PTP), for the YEARS algorithm and for the Pulmonary Embolism Rule-out Criteria (PERC). All strategies were tested separately in each healthcare setting. Following studies done in this field, the primary diagnostic metrices estimated from the models were the "failure rate" of each strategy-i.e., the proportion of missed PE among patients categorized as "PE excluded" and "efficiency"-defined as the proportion of patients categorized as "PE excluded" among all patients. In self-referral emergency care, the PERC algorithm excludes PE in 21% of suspected patients at a failure rate of 1.12% (95% confidence interval [CI] 0.74 to 1.70), whereas this increases to 6.01% (4.09 to 8.75) in referred patients to secondary care at an efficiency of 10%. In patients from primary healthcare and those referred to secondary care, strategies adjusting D-dimer to PTP are the most efficient (range: 43% to 62%) at a failure rate ranging between 0.25% and 3.06%, with higher failure rates observed in patients referred to secondary care. For this latter setting, strategies adjusting D-dimer to age are associated with a lower failure rate ranging between 0.65% and 0.81%, yet are also less efficient (range: 33% and 35%). For all strategies, failure rates are highest in hospitalized or nursing home patients, ranging between 1.68% and 5.13%, at an efficiency ranging between 15% and 30%. The main limitation of the primary analyses was that the diagnostic performance of each strategy was compared in different sets of studies since the availability of items used in each diagnostic strategy differed across included studies; however, sensitivity analyses suggested that the findings were robust. CONCLUSIONS: The capability of safely and efficiently ruling out PE of available diagnostic strategies differs for different healthcare settings. The findings of this IPD MA help in determining the optimum diagnostic strategies for ruling out PE per healthcare setting, balancing the trade-off between failure rate and efficiency of each strategy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.032
metaresearch head score (Gemma)0.071
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.032
Threshold uncertainty score0.172

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0320.071
Meta-epidemiology (narrow)0.0030.001
Meta-epidemiology (broad)0.0170.046
Bibliometrics0.0080.009
Science and technology studies0.0010.001
Scholarly communication0.0030.002
Open science0.0030.002
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.345
GPT teacher head0.422
Teacher spread0.077 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations44
Published2022
Admission routes2
Has abstractyes

Explore more

Same venuePLoS MedicineSame topicVenous Thromboembolism Diagnosis and ManagementFrench-language works237,207