MétaCan
Menu
Back to cohort
Record W4210371543 · doi:10.1088/1361-6501/ac5133

CAD-based x-ray CT calibration and error compensation

2022· article· en· W4210371543 on OpenAlexaff
Cédric Fragnaud, Clément Remacha, Julián Betancur, Stéphane Roux

Bibliographic record

VenueMeasurement Science and Technology · 2022
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsSafran Electronics (Canada)
FundersAssociation Nationale de la Recherche et de la Technologie
KeywordsCalibrationScannerComputer scienceIndustrial computed tomographyCADProjection (relational algebra)Pencil (optics)Computer Aided DesignAlgorithmParametrization (atmospheric modeling)Orthographic projectionComputer visionTomographyOpticsArtificial intelligenceMathematicsPhysicsEngineering drawing

Abstract

fetched live from OpenAlex

Abstract Artifacts due to imperfect determination of the scanner geometry, beam hardening (BH), and diffuse Compton scattering, limit the quantitative exploitation of radiographs or tomographies for non-destructive evaluation. Exploiting the computer-aided design (CAD) model of an industrial part, a methodology is proposed to refine the estimation of the computed tomography (CT)-scanner geometry up to a scale factor, to correct or account for artifacts, and to assess the metrology of the part. A projective model describing the formation of x-ray images in CT-scanners is first introduced. The optimal parameters of the projective model are identified using a novel CAD-based calibration method that relies on the registration of simulated projections onto experimental ones. A metrological analysis based on the comparison between acquired and simulated x-ray images is proposed. A turbine blade, for which an automatic inspection procedure from few views is under development, is used as an example to illustrate the proposed methodology. The parametrization accounts for the refinement of the projection geometry, the calibration of BH, and the estimation of scattering. It is shown that, using the proposed procedure, the differences between acquired and simulated radiographic images are significantly reduced, indicating that the optimal parameters are properly identified. These differences are then exploited to detect flaws in the part.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.813
Threshold uncertainty score0.310

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.223
Teacher spread0.201 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueMeasurement Science and TechnologySame topicAdvanced X-ray and CT ImagingFrench-language works237,207