Abstract
Abstract Objective . The assessment of lung mechanics in horses is nowadays based on invasive methods that may require sedation. The forced oscillation technique (FOT) allows the non-invasive assessment of respiratory mechanics during spontaneous breathing, but current devices are complex, cumbersome, expensive, and difficult to be applied in horses. Approach . We developed a portable FOT device based on a novel approach in which the pressure waveforms are generated by a servo-controlled ducted fan. This new approach allows the design of devices that are more sturdy, compact, and portable compared to already existing approaches. The prototype includes 1) a small microcontroller-based electronic board for controlling the fan and measuring flow and pressure and 2) an optimized data processing algorithm. Main results . This device provides a maximum error of 0.06 cmH 2 O·s/L and 0.15 cmH 2 O·s/L in measuring respiratory resistance and reactance during in-vitro validation. A pilot study was also performed on three healthy horses and three horses with severe equine asthma (SEA) and it demonstrated good tolerability and feasibility of the new device. Total respiratory system resistance ( R rs ) and reactance ( X rs ) significantly differed ( p < 0.05) between groups. At 5 Hz, R rs was 0.66 ± 0.02 cmH 2 O·s/L and 0.94 ± 0.07 cmH 2 O·s/L in healthy and in SEA, respectively. X rs 0.38 ± 0.02 cmH 2 O·s/L and −0.27 ± 0.05 cmH 2 O·s/L. Significance . This novel approach for applying FOT allowed the development of a small, affordable, and portable device for the non-invasive evaluation of respiratory mechanics in spontaneously breathing horses, providing a useful new tool for improving veterinary respiratory medicine. Moreover, our results provide supporting evidence of the value of this novel approach for developing portable FOT devices also for applications in humans.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.005 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".