MétaCan
Menu
Back to cohort
Record W4210496038 · doi:10.1088/1361-6579/ac522e

A portable fan-based device for evaluating lung function in horses by the forced oscillation technique

2022· article· en· W4210496038 on OpenAlexaff
Davide Bizzotto, Stefano Paganini, Luca Stucchi, Matteo Palmisano Avallone, Esther M. Millares‐Ramirez, Pasquale Pio Pompilio, Francesco Ferrucci, Jean‐Pierre Lavoie, Raffaele L. Dellacá

Bibliographic record

VenuePhysiological Measurement · 2022
Typearticle
Languageen
FieldVeterinary
TopicVeterinary Equine Medical Research
Canadian institutionsUniversité de MontréalCegep de Saint Hyacinthe
Fundersnot available
KeywordsForced oscillationComputer scienceReactanceLung functionMedicineBiomedical engineeringSimulationEngineeringLungElectrical engineeringVoltageElectrical impedance

Abstract

fetched live from OpenAlex

Abstract Objective . The assessment of lung mechanics in horses is nowadays based on invasive methods that may require sedation. The forced oscillation technique (FOT) allows the non-invasive assessment of respiratory mechanics during spontaneous breathing, but current devices are complex, cumbersome, expensive, and difficult to be applied in horses. Approach . We developed a portable FOT device based on a novel approach in which the pressure waveforms are generated by a servo-controlled ducted fan. This new approach allows the design of devices that are more sturdy, compact, and portable compared to already existing approaches. The prototype includes 1) a small microcontroller-based electronic board for controlling the fan and measuring flow and pressure and 2) an optimized data processing algorithm. Main results . This device provides a maximum error of 0.06 cmH 2 O·s/L and 0.15 cmH 2 O·s/L in measuring respiratory resistance and reactance during in-vitro validation. A pilot study was also performed on three healthy horses and three horses with severe equine asthma (SEA) and it demonstrated good tolerability and feasibility of the new device. Total respiratory system resistance ( R rs ) and reactance ( X rs ) significantly differed ( p < 0.05) between groups. At 5 Hz, R rs was 0.66 ± 0.02 cmH 2 O·s/L and 0.94 ± 0.07 cmH 2 O·s/L in healthy and in SEA, respectively. X rs 0.38 ± 0.02 cmH 2 O·s/L and −0.27 ± 0.05 cmH 2 O·s/L. Significance . This novel approach for applying FOT allowed the development of a small, affordable, and portable device for the non-invasive evaluation of respiratory mechanics in spontaneously breathing horses, providing a useful new tool for improving veterinary respiratory medicine. Moreover, our results provide supporting evidence of the value of this novel approach for developing portable FOT devices also for applications in humans.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.941
Threshold uncertainty score0.710

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0050.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.368
GPT teacher head0.439
Teacher spread0.071 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2022
Admission routes1
Has abstractyes

Explore more

Same venuePhysiological MeasurementSame topicVeterinary Equine Medical ResearchFrench-language works237,207