Record W4210963337 · doi:10.3390/s22041321

User-Independent Hand Gesture Recognition Classification Models Using Sensor Fusion

2022· article· en· W4210963337 on OpenAlexafffund
J. Guillermo Colli Alfaro, Ana Luisa Trejos

Bibliographic record

VenueSensors · 2022
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsWestern University
FundersMinistero dello Sviluppo EconomicoOntario Ministry of Research and InnovationNatural Sciences and Engineering Research Council of CanadaConsejo Nacional de Ciencia y Tecnología
KeywordsGestureWearable computerInertial measurement unitGesture recognitionComputer scienceInterface (matter)Artificial intelligenceSensor fusionSupport vector machineMechatronicsExoskeletonHuman–computer interactionSpeech recognitionMachine learningPattern recognition (psychology)SimulationEmbedded system

Abstract

fetched live from OpenAlex

Recently, it has been proven that targeting motor impairments as early as possible while using wearable mechatronic devices for assisted therapy can improve rehabilitation outcomes. However, despite the advanced progress on control methods for wearable mechatronic devices, the need for a more natural interface that allows for better control remains. To address this issue, electromyography (EMG)-based gesture recognition systems have been studied as a potential solution for human-machine interface applications. Recent studies have focused on developing user-independent gesture recognition interfaces to reduce calibration times for new users. Unfortunately, given the stochastic nature of EMG signals, the performance of these interfaces is negatively impacted. To address this issue, this work presents a user-independent gesture classification method based on a sensor fusion technique that combines EMG data and inertial measurement unit (IMU) data. The Myo Armband was used to measure muscle activity and motion data from healthy subjects. Participants were asked to perform seven types of gestures in four different arm positions while using the Myo on their dominant limb. Data obtained from 22 participants were used to classify the gestures using three different classification methods. Overall, average classification accuracies in the range of 67.5-84.6% were obtained, with the Adaptive Least-Squares Support Vector Machine model obtaining accuracies as high as 92.9%. These results suggest that by using the proposed sensor fusion approach, it is possible to achieve a more natural interface that allows better control of wearable mechatronic devices during robot assisted therapies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.004
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.231
Teacher spread0.189 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations63
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueSensorsSame topicMuscle activation and electromyography studiesFrench-language works237,207