Enhanced FIB-SEM systems for large-volume 3D imaging
Why is this work in the frame?
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Full frame distilled prediction
Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
- Candidate categories
- none
- Consensus categories
- none
- Domain
- Candidate signal: noneConsensus signal: none
- Study design
- Candidate signal: Bench or experimentalConsensus signal: Bench or experimental
- Genre
- Candidate signal: EmpiricalConsensus signal: none
- Teacher disagreement score
- 0.932
- Threshold uncertainty score
- 0.400
- Validation status
machine_predicted_unvalidated·codex-gemma-dda1882f352a
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
- Teacher spread
- 0.325 · how far apart the two teachers sit on this one work
- Validation status
score_only:v0-immature-baseline· verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it
Abstract
Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 106 µm3. These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processes and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
The record
- Venue
- eLife
- Topic
- Advanced Electron Microscopy Techniques and Applications
- Field
- Biochemistry, Genetics and Molecular Biology
- Canadian institutions
- Dalhousie University
- Funders
- National Institutes of HealthGordon and Betty Moore FoundationNational Institute of Neurological Disorders and StrokeU.S. Department of EnergyHoward Hughes Medical Institute
- Keywords
- Volume (thermodynamics)NanotechnologyMaterials sciencePhysics
- Has abstract in OpenAlex
- yes