MétaCan
Menu
← Back to cohort
Record W4212893186 · doi:10.21203/rs.2.22418/v2

Reliability of Tibiofemoral Contact Area and Centroid Location in an Upright, Open MRI (UO-MRI)

2020· preprint· en· W4212893186 on OpenAlexafffund
Andrew Schmidt, David J. Stockton, Michael A. Hunt, Andrew Yung, Bassam A. Masri, David R. Wilson

Bibliographic record

VenueResearch Square · 2020
Typepreprint
Languageen
FieldMedicine
TopicKnee injuries and reconstruction techniques
Canadian institutionsUniversity of British Columbia
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchCanadian Orthopaedic Foundation
KeywordsCentroidSagittal planeReliability (semiconductor)Contact areaCoronal planeMagnetic resonance imagingNuclear medicineLimits of agreementStandard errorMedicineContact forceOrthodonticsBiomedical engineeringMathematicsComputer scienceAnatomyMaterials sciencePhysicsArtificial intelligenceStatisticsRadiology

Abstract

fetched live from OpenAlex

Abstract Background: Biomechanical studies are often performed using conventional closed-bore MR, which has necessitated simulating weightbearing load on the joint. The clinical applicability of these biomechanical findings is unclear because of the limitations of simulating weightbearing. Upright, open MRI (UO-MRI) can be used to assess knee joint mechanics, in particular contact area and centroid location. However, it is not clear how reliably measurements of contact area and centroid location can be made in upright weightbearing postures. Methods: Manual segmentation of cartilage regions in contact was performed and centroids of those contact areas were automatically determined for the medial (MC) and lateral (LC) tibiofemoral compartments. To assess reliability, inter-rater, test-retest, and intra-rater reliability were determined by intra-class correlation (ICC 3,1 ), standard error of measurement (SEM), smallest detectable change with 95% confidence (SDC 95 ). Accuracy was assessed by using a high-resolution, 7T MRI as a reference and determined by measurement error (%). Results: Contact area and centroid location reliability (inter-rater, test-retest, and intra-rater) for sagittal scans in the MC demonstrated ICC 3,1 values from 0.95-0.99 and 0.98-0.99 respectively, and in the LC from 0.83-0.91 and 0.95-1.00 respectively. The smallest detectable change in contact area was 1.28% in the MC and 0.95% in the LC. Contact area and centroid location reliability for coronal scans in the MC demonstrated ICC 3,1 values from 0.90-0.98 and 0.98-1.00 respectively, and in the LC from 0.76-0.94 and 0.93-1.00 respectively. The smallest detectable change in contact area was 0.65% in the MC and 1.41% in the LC. Contact area segmentation was accurate to within 4.81% measurement error. Conclusions: Knee contact area and contact centroid location can be assessed in upright weightbearing MRI with good to excellent reliability and accuracy within 5%. The lower field strength used in upright, weightbearing MRI does not compromise the reliability of tibiofemoral contact area and centroid location measures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.016
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.031

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.016
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.079
GPT teacher head0.430
Teacher spread0.351 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueResearch Square→Same topicKnee injuries and reconstruction techniques→French-language works237,207→