MétaCan
Menu
Back to cohort
Record W4212905789 · doi:10.1101/2022.02.18.481050

Deep learning accurately quantifies plasma cell percentages on CD138-stained bone marrow samples

2022· preprint· en· W4212905789 on OpenAlexaff
Fred Fu, Angela Guenther, Ali Sakhdari, Trevor D. McKee, Daniel Xia

Bibliographic record

VenuebioRxiv (Cold Spring Harbor Laboratory) · 2022
Typepreprint
Languageen
FieldComputer Science
TopicDigital Imaging for Blood Diseases
Canadian institutionsThe Scarborough HospitalUniversity Health Network
Fundersnot available
KeywordsConvolutional neural networkArtificial intelligenceDeep learningComputer scienceSegmentationSoftwarePattern recognition (psychology)PathologyMedicine

Abstract

fetched live from OpenAlex

Abstract Background The diagnosis of plasma cell neoplasms requires accurate, and ideally precise, percentages. This plasma cell percentage is often determined by visual estimation of CD138-stained bone marrow biopsies and clot sections. While not necessarily inaccurate, estimates are by definition imprecise. For this study, we hypothesized that deep learning can be used to improve precision. Methods We trained a semantic segmentation-based convolutional neural network (CNN) using annotations of CD138+ and CD138− cells provided by one pathologist on small image patches of bone marrow and validated the CNN on an independent test set of images patches using annotations from two pathologists and a non-deep-learning commercial software. Once satisfied with performance, we scaled-up the CNN to evaluate whole slide images (WSIs), and deployed the system as a workflow friendly web application to measure plasma cell percentages using snapshots taken from microscope cameras. Results On validation image patches, we found that the intraclass correlation coefficients for plasma cell percentages between the CNN and pathologist #1, a non-deep learning commercial software and pathologist #1, and pathologists #1 and #2 were 0.975, 0.892, and 0.994, respectively. The overall results show that CNN labels were almost as accurate pathologist labels at a cell-by-cell level. On WSIs from 10 clinical cases, the CNN continued to perform well, and identified two cases where the sign-out pathologist overestimated plasma cell percentages. Conclusions The high labeling accuracy of the CNN supports its eventually application as a computational second-opinion tool for the measurement of plasma cell percentages in clinical practice.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Scholarly communication
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.148
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0030.001
Open science0.0030.004
Research integrity0.0000.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.240
Teacher spread0.215 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2022
Admission routes1
Has abstractyes

Explore more

Same venuebioRxiv (Cold Spring Harbor Laboratory)Same topicDigital Imaging for Blood DiseasesFrench-language works237,207