MétaCan
Menu
Back to cohort
Record W4213278527 · doi:10.2196/35642

Visual Attention of Anesthesia Providers in Simulated Anesthesia Emergencies Using Conventional Number-Based and Avatar-Based Patient Monitoring: Prospective Eye-Tracking Study

2022· article· en· W4213278527 on OpenAlexvenueno aff
Arsène Ljubenovic, Sadiq Said, Julia Braun, Bastian Grande, Michaela Kolbe, Donat R. Spahn, Christoph B. Nöthiger, David W. Tscholl, Tadzio R. Roche

Bibliographic record

VenueJMIR Serious Games · 2022
Typearticle
Languageen
FieldMedicine
TopicHealthcare Technology and Patient Monitoring
Canadian institutionsnot available
Fundersnot available
KeywordsEye trackingSituation awarenessPatient safetyPerioperativeFixation (population genetics)Visual attentionTask (project management)Eye surgeryMedicineAvatarMedical emergencyComputer scienceSurgeryHealth careCognitionArtificial intelligenceHuman–computer interactionPsychiatryPopulation

Abstract

fetched live from OpenAlex

BACKGROUND: Inadequate situational awareness accounts for two-thirds of preventable complications in anesthesia. An essential tool for situational awareness in the perioperative setting is the patient monitor. However, the conventional monitor has several weaknesses. Avatar-based patient monitoring may address these shortcomings and promote situation awareness, a prerequisite for good decision making. OBJECTIVE: The spatial distribution of visual attention is a fundamental process for achieving adequate situation awareness and thus a potential quantifiable surrogate for situation awareness. Moreover, measuring visual attention with a head-mounted eye-tracker may provide insights into usage and acceptance of the new avatar-based patient monitoring modality. METHODS: This prospective eye-tracking study compared anesthesia providers' visual attention on conventional and avatar-based patient monitors during simulated critical anesthesia events. We defined visual attention, measured as fixation count and dwell time, as our primary outcome. We correlated visual attention with the potential confounders: performance in managing simulated critical anesthesia events (task performance), work experience, and profession. We used mixed linear models to analyze the results. RESULTS: Fifty-two teams performed 156 simulations. After a manual quality check of the eye-tracking footage, we excluded 57 simulations due to technical problems and quality issues. Participants had a median of 198 (IQR 92.5-317.5) fixations on the patient monitor with a median dwell time of 30.2 (IQR 14.9-51.3) seconds. We found no significant difference in participants' visual attention when using avatar-based patient monitoring or conventional patient monitoring. However, we found that with each percentage point of better task performance, the number of fixations decreased by about 1.39 (coefficient -1.39; 95% CI -2.44 to -0.34; P=.02), and the dwell time diminished by 0.23 seconds (coefficient -0.23; 95% CI: -0.4 to -0.06; P=.01). CONCLUSIONS: Using eye tracking, we found no significant difference in visual attention when anesthesia providers used avatar-based monitoring or conventional patient monitoring in simulated critical anesthesia events. However, we identified visual attention in conjunction with task performance as a surrogate for situational awareness.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.011
Threshold uncertainty score0.950

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.355
Teacher spread0.326 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJMIR Serious GamesSame topicHealthcare Technology and Patient MonitoringFrench-language works237,207