MétaCan
Menu
Back to cohort
Record W4213439502 · doi:10.1097/bpo.0000000000002110

Prolonged Brace Treatment Does Not Result in Improved Acetabular Indices in Infantile Dislocated Hips

2022· article· en· W4213439502 on OpenAlexaff

Bibliographic record

VenueJournal of Pediatric Orthopaedics · 2022
Typearticle
Languageen
FieldMedicine
TopicHip disorders and treatments
Canadian institutionsHospital for Sick Children
Fundersnot available
KeywordsBraceAcetabulumOrthopedic surgeryCongenital diseaseLower limb

Abstract

fetched live from OpenAlex

BACKGROUND: The Pavlik harness (PH) is commonly used to treat infantile dislocated hips. However, significant variability exists in the duration of brace treatment after successful reduction of the dislocated hip. The purpose of this study was to evaluate the effect of prescribed time in brace on acetabular index (AI) at two years of age using a prospective, international, multicenter database. METHODS: We retrospectively studied prospectively enrolled infants with at least 1 dislocated hip that were initially treated with a PH and had a recorded AI at 2-year follow-up. Subjects were treated at 1 of 2 institutions. Institution 1 used the PH until they observed normal radiographic acetabular development. Institution 2 followed a structured shorter brace treatment protocol. Hip dislocation was defined as <30% femoral head coverage at rest on the pretreatment ultrasound or International Hip Dysplasia Institute (IHDI) grade III or IV on the pretreatment radiograph. RESULTS: Fifty-three hips met our inclusion criteria. Hips from Institution 1 were treated with a brace ×3 longer than hips from institution 2 (adjusted mean 8.9±1.3 vs. 2.6±0.2 mo) (P<0.001). Institution 1 had an 88% success rate and institution 2 had an 85% success rate at achieving hip reduction (P=0.735). At 2-year follow-up, we observed no significant difference in AI between Institution 1 (adjusted mean 25.6±0.9 degrees) compared with Institution 2 (adjusted mean 23.5±0.8 degrees) (P=0.1). However, 19% of patients from Institution 1 and 44% of patients from Institution 2 were at or below the 50th percentile of previously published age-matched and sex-matched AI normal data (P=0.049). Also, 27% (7/26) of hips from Institution 1 had significant acetabular dysplasia (more than 2 SD from the mean), compared with a 22% (6/27) from Institution 2 (P=0.691). We found no correlation between age at initiation of bracing and AI at 2-year follow-up (P=0.071). CONCLUSIONS: The PH brace can successfully treat dislocated infant hips, however, prolonged brace treatment was not found to result in improved acetabular development at 2-year follow-up. LEVEL OF EVIDENCE: Level III.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.042
Threshold uncertainty score0.683

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.267
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Pediatric OrthopaedicsSame topicHip disorders and treatmentsFrench-language works237,207