MétaCan
Menu
Back to cohort
Record W4214903080 · doi:10.1088/1361-6560/ac5a93

Effect of dataset size, image quality, and image type on deep learning-based automatic prostate segmentation in 3D ultrasound

2022· article· en· W4214903080 on OpenAlexafffund
Nathan Orlando, Igor Gyacskov, Derek J. Gillies, Fumin Guo, Cesare Romagnoli, David D’Souza, Derek W. Cool, Douglas A. Hoover, Aaron Fenster

Bibliographic record

VenuePhysics in Medicine and Biology · 2022
Typearticle
Languageen
FieldMedicine
TopicProstate Cancer Diagnosis and Treatment
Canadian institutionsUniversity of TorontoLondon Health Sciences CentreWestern University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchOntario Institute for Cancer Research
KeywordsComputer scienceArtificial intelligenceSegmentationDeep learningImage qualityPattern recognition (psychology)Computer visionImage (mathematics)

Abstract

fetched live from OpenAlex

Three-dimensional (3D) transrectal ultrasound (TRUS) is utilized in prostate cancer diagnosis and treatment, necessitating time-consuming manual prostate segmentation. We have previously developed an automatic 3D prostate segmentation algorithm involving deep learning prediction on radially sampled 2D images followed by 3D reconstruction, trained on a large, clinically diverse dataset with variable image quality. As large clinical datasets are rare, widespread adoption of automatic segmentation could be facilitated with efficient 2D-based approaches and the development of an image quality grading method. The complete training dataset of 6761 2D images, resliced from 206 3D TRUS volumes acquired using end-fire and side-fire acquisition methods, was split to train two separate networks using either end-fire or side-fire images. Split datasets were reduced to 1000, 500, 250, and 100 2D images. For deep learning prediction, modified U-Net and U-Net++ architectures were implemented and compared using an unseen test dataset of 40 3D TRUS volumes. A 3D TRUS image quality grading scale with three factors (acquisition quality, artifact severity, and boundary visibility) was developed to assess the impact on segmentation performance. For the complete training dataset, U-Net and U-Net++ networks demonstrated equivalent performance, but when trained using split end-fire/side-fire datasets, U-Net++ significantly outperformed the U-Net. Compared to the complete training datasets, U-Net++ trained using reduced-size end-fire and side-fire datasets demonstrated equivalent performance down to 500 training images. For this dataset, image quality had no impact on segmentation performance for end-fire images but did have a significant effect for side-fire images, with boundary visibility having the largest impact. Our algorithm provided fast (<1.5 s) and accurate 3D segmentations across clinically diverse images, demonstrating generalizability and efficiency when employed on smaller datasets, supporting the potential for widespread use, even when data is scarce. The development of an image quality grading scale provides a quantitative tool for assessing segmentation performance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.018
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.008
Threshold uncertainty score0.040

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0080.018
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.071
GPT teacher head0.422
Teacher spread0.351 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations37
Published2022
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicProstate Cancer Diagnosis and TreatmentFrench-language works237,207