MétaCan
Menu
Back to cohort
Record W4220665407 · doi:10.3390/jcm11061608

Metallic versus Non-Metallic Cerclage Cables System in Periprosthetic Hip Fracture Treatment: Single-Institution Experience at a Minimum 1-Year Follow-Up

2022· article· en· W4220665407 on OpenAlexaboutno aff
Attilio Speranza, Carlo Massafra, Stefano Pecchia, Riccardo Di Niccolo, Raffaele Iorio, Andrea Ferretti

Bibliographic record

VenueJournal of Clinical Medicine · 2022
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsPeriprostheticMedicineSurgeryRadiological weaponRetrospective cohort studyInternal fixationFixation (population genetics)ComplicationHarris Hip ScoreRadiographyArthroplastyPopulation

Abstract

fetched live from OpenAlex

Metallic cerclage cables are reliable and cost-effective internal fixation devices, which are largely used in surgical practice for the treatment of periprosthetic fractures. Nevertheless, complications connected with their use have been described in the literature, including the following: third-body generation, failure and consequent migration, fraying, allergies, and injury to the surgical team. The development of new materials offers alternatives to traditional metallic cables. This study compares the outcomes between two groups of patients affected by periprosthetic hip fractures, treated with titanium cables or with ultra-high-molecular-weight polyethylene (UHMWPe) iso-elastic cables. Our retrospective study aims to compare the clinical and radiological outcomes of titanium cables and UHMWPe iso-elastic cables, isolated or associated with dedicated plates, for the surgical treatment of periprosthetic fractures with stable implants. Two groups of 30 (group A-metallic cables) and 24 (group B-UHMWPe iso-elastic cables) patients have been surgically treated in our institution for hip periprosthetic fractures, between September 2017 and June 2020. The mean age of the patients was 81 years in group A and 80 years in group B. In our study, we included fractures classified as B1 or C, according to the Vancouver postoperative fractures classification; the patients were evaluated retrospectively at 1 year postoperatively, regarding the following: surgery time, blood loss, partial weight-bearing time, radiographical healing time, Harris hip score, and postoperative complications. Comparable outcomes were observed in patients from both groups. Group A showed a higher complication rate compared to group B, at 1 year postoperatively. Non-metallic nylon fiber and ultra-high-molecular-weight polyethylene (UHMWPe) cerclage cables could represent a reliable fixation device, ensuring comparable healing and complication rates with traditional titanium cerclage cables.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.072
GPT teacher head0.360
Teacher spread0.289 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Clinical MedicineSame topicOrthopaedic implants and arthroplastyFrench-language works237,207