MétaCan
Menu
Back to cohort
Record W4220689132 · doi:10.1097/mcc.0000000000000937

Cardiac output monitoring – invasive and noninvasive

2022· review· en· W4220689132 on OpenAlexaff
Virendra K. Arya, Waiel Al-Moustadi, Vikas Dutta

Bibliographic record

VenueCurrent Opinion in Critical Care · 2022
Typereview
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsUniversity of ManitobaSt. Boniface Hospital
Fundersnot available
KeywordsMedicinePulmonary artery catheterCritically illGold standard (test)Intensive careIntensive care medicineClinical PracticeStandard of careCardiac outputCatheterRadiologyCardiologyInternal medicineHemodynamics

Abstract

fetched live from OpenAlex

PURPOSE OF REVIEW: The purpose of this article is to review various contemporary cardiac output (CO) measurement technologies available and their utility in critically ill patients. RECENT FINDINGS: CO measurement devices can be invasive, minimally invasive, or noninvasive depending upon their method of CO measurement. All devices have pros and cons, with pulmonary artery catheter (PAC) being the gold standard. The invasive techniques are more accurate; however, their invasiveness can cause more complications. The noninvasive devices predict CO via mathematical modeling with several assumptions and are thus prone to errors in clinical situations. Recently, PAC has made a comeback into clinical practice especially in cardiac intensive care units (ICUs). Critical care echocardiography (CCE) is an upcoming tool that not only provides CO but also helps in differential diagnosis. Lack of proper training and nonavailability of equipment are the main hindrances to the wide adoption of CCE. SUMMARY: PAC thermodilution for CO measurement is still gold standard and most suitable in patients with cardiac pathology and with experienced user. CCE offers an alternative to thermodilution and is suitable for all ICUs; however, structural training is required.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.956
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.300
GPT teacher head0.494
Teacher spread0.194 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueCurrent Opinion in Critical CareSame topicHemodynamic Monitoring and TherapyFrench-language works237,207