MétaCan
Menu
Back to cohort
Record W4220809636 · doi:10.1007/s00590-022-03240-z

The role of cerclage wiring in the management of subtrochanteric and reverse oblique intertrochanteric fractures: a meta-analysis of comparative studies

2022· review· en· W4220809636 on OpenAlexaboutno aff
Ashraf T. Hantouly, Motasem Salameh, Ahmad A. Toubasi, Loay A. Salman, Osama Alzobi, Abdulaziz F. Ahmed, Ghalib Ahmed

Bibliographic record

VenueEuropean Journal of Orthopaedic Surgery & Traumatology · 2022
Typereview
Languageen
FieldMedicine
TopicHip and Femur Fractures
Canadian institutionsnot available
FundersQatar National LibraryHamad Medical Corporation
KeywordsMedicineIntramedullary rodSurgeryFixation (population genetics)ComplicationBlood lossReduction (mathematics)Bony unionInternal fixationPopulation

Abstract

fetched live from OpenAlex

PURPOSE: Subtrochanteric and reverse oblique intertrochanteric fractures are challenging and often difficult to reduce. While intramedullary nailing (IMN) is considered the standard treatment, achieving anatomic reduction prior to fixation is essential. This study aimed to assess the impact of cerclage wiring with IMN on the outcomes and complication rate in treating subtrochanteric and reverse oblique intertrochanteric fractures. METHODS: This meta-analysis was conducted in line with PRISMA guidelines. The primary outcome was the time to union. The secondary outcomes were operative time, blood loss, quality of reduction, reduction alignment (if in varus), complications and reoperations. PubMed, Cochrane, Web of Science and Google Scholar were searched till July 2021. Articles that compared intramedullary nailing (IMN) versus intramedullary nailing and cerclage wiring (IMN-C) in the treatment of subtrochanteric and reverse oblique intertrochanteric fractures were included. The risk of bias was assessed using the Newcastle-Ottawa scale. RESULTS: This meta-analysis included 415 patients with subtrochanteric and reverse oblique intertrochanteric fracture from six comparative studies. Our findings showed that IMN-C was significantly associated with higher mean duration of surgery and blood loss. However, IMN-C had significantly lower mean time to union compared to IMN alone. In addition, IMN-C had lower pooled prevalence of varus reduction and overall complications. CONCLUSION: This study showed that the use of cerclage wiring is associated with lower time to union, lower prevalence of varus reduction and overall complications. Therefore, cerclage wiring augmentation is a safe technique with low complication rate and may be advised whenever open reduction is needed in the management of subtrochanteric and reverse oblique intertrochanteric fractures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.540
Threshold uncertainty score0.842

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0060.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0070.004
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.193
GPT teacher head0.390
Teacher spread0.197 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Journal of Orthopaedic Surgery & TraumatologySame topicHip and Femur FracturesFrench-language works237,207