Patient Satisfaction and Visual Function Following Implantation of Trifocal or Extended Range of Vision Intraocular Lenses

2022· article· en· W4220842062 on OpenAlexaffabout

Bibliographic record

VenueClinical ophthalmology · 2022
Typearticle
Languageen
FieldMedicine
TopicOphthalmology and Visual Impairment Studies
Canadian institutionsKensington HealthPublic Health OntarioUniversity of Toronto
Fundersnot available
KeywordsIntraocular lensesPatient satisfactionContrast (vision)Visual acuityMultifocal intraocular lensPresbyopia

Abstract

fetched live from OpenAlex

Purpose: To compare the trifocal TFNT00 and extended depth-of-focus (EDF) ZXR00 intraocular lenses (IOLs) with respect to overall satisfaction with near and distance vision, visual acuity, dysphotopsia symptoms, spectacle dependence, and mesopic best corrected contrast sensitivity (MBCCS). Materials and Methods: This non-randomized, retrospective, single-centre, comparative study took place at the Kensington Eye Institute in Toronto, Canada. Subjects implanted with either the TFNT00 IOL (n = 11) or ZXR00 IOL (n = 13) were assessed up to 4 years post operatively. Overall satisfaction with distance and near vision, corrected distance visual acuity, uncorrected visual acuity at distance, intermediate (60 cm) and near (40 cm) (UNVA), dysphotopsia symptoms, spectacle dependence and monocular MBCCS were evaluated. Results: Forty-eight eyes of 24 subjects (mean age 68 years, 54% female) were assessed. There was no difference in overall satisfaction; both groups had a median score of 10/10 for overall distance vision, and 7/10 and 8/10 for near vision for EDF and trifocal, respectively. MBCCS at the higher spatial frequencies was significantly better with the ZXR00 IOL. Potentially clinically relevant but not statistically significant differences were found; the trifocal group (vs the EDF group) had better binocular UNVA (20/24 vs 20/32) and less spectacle dependence at least some of the time (54% vs 85%). Conclusion: The ZXR00 may be preferred for those who want optimal contrast sensitivity in dim lighting. Consistent with previous studies, the TFNT00 trifocal IOL may be a better choice for those who want to optimize UNVA. More studies in North America are required to further investigate spectacle dependence.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.054
Threshold uncertainty score0.463

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.057
GPT teacher head0.432
Teacher spread0.376 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueClinical ophthalmologySame topicOphthalmology and Visual Impairment StudiesFrench-language works237,207