MétaCan
Menu
Back to cohort
Record W4220886599 · doi:10.1002/mp.15632

Spatially tracked whole‐breast three‐dimensional ultrasound system toward point‐of‐care breast cancer screening in high‐risk women with dense breasts

2022· article· en· W4220886599 on OpenAlexafffund
Claire Keun Sun Park, Shuwei Xing, Samuel Papernick, Nathan Orlando, Eric Knull, Carla du Toit, Jeffrey Bax, Lori Gardi, Kevin Barker, David Tessier, Aaron Fenster

Bibliographic record

VenueMedical Physics · 2022
Typearticle
Languageen
FieldMedicine
TopicDigital Radiography and Breast Imaging
Canadian institutionsLondon Health Sciences CentreRobarts Clinical TrialsWestern University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health Research
KeywordsBreast cancerVisualizationComputer visionMammographyMedical imagingImage registrationArtificial intelligenceMedicineBreast imagingComputer scienceMedical physicsRadiologyCancerImage (mathematics)

Abstract

fetched live from OpenAlex

Abstract Background Mammographic screening has reduced mortality in women through the early detection of breast cancer. However, the sensitivity for breast cancer detection is significantly reduced in women with dense breasts, in addition to being an independent risk factor. Ultrasound (US) has been proven effective in detecting small, early‐stage, and invasive cancers in women with dense breasts. Purpose To develop an alternative, versatile, and cost‐effective spatially tracked three‐dimensional (3D) US system for whole‐breast imaging. This paper describes the design, development, and validation of the spatially tracked 3DUS system, including its components for spatial tracking, multi‐image registration and fusion, feasibility for whole‐breast 3DUS imaging and multi‐planar visualization in tissue‐mimicking phantoms, and a proof‐of‐concept healthy volunteer study. Methods The spatially tracked 3DUS system contains (a) a six‐axis manipulator and counterbalanced stabilizer, (b) an in‐house quick‐release 3DUS scanner, adaptable to any commercially available US system, and removable, allowing for handheld 3DUS acquisition and two‐dimensional US imaging, and (c) custom software for 3D tracking, 3DUS reconstruction, visualization, and spatial‐based multi‐image registration and fusion of 3DUS images for whole‐breast imaging. Spatial tracking of the 3D position and orientation of the system and its joints (J 1–6 ) were evaluated in a clinically accessible workspace for bedside point‐of‐care (POC) imaging. Multi‐image registration and fusion of acquired 3DUS images were assessed with a quadrants‐based protocol in tissue‐mimicking phantoms and the target registration error (TRE) was quantified. Whole‐breast 3DUS imaging and multi‐planar visualization were evaluated with a tissue‐mimicking breast phantom. Feasibility for spatially tracked whole‐breast 3DUS imaging was assessed in a proof‐of‐concept healthy male and female volunteer study. Results Mean tracking errors were 0.87 ± 0.52, 0.70 ± 0.46, 0.53 ± 0.48, 0.34 ± 0.32, 0.43 ± 0.28, and 0.78 ± 0.54 mm for joints J 1–6 , respectively. Lookup table (LUT) corrections minimized the error in joints J 1 , J 2 , and J 5 . Compound motions exercising all joints simultaneously resulted in a mean tracking error of 1.08 ± 0.88 mm ( N = 20) within the overall workspace for bedside 3DUS imaging. Multi‐image registration and fusion of two acquired 3DUS images resulted in a mean TRE of 1.28 ± 0.10 mm. Whole‐breast 3DUS imaging and multi‐planar visualization in axial, sagittal, and coronal views were demonstrated with the tissue‐mimicking breast phantom. The feasibility of the whole‐breast 3DUS approach was demonstrated in healthy male and female volunteers. In the male volunteer, the high‐resolution whole‐breast 3DUS acquisition protocol was optimized without the added complexities of curvature and tissue deformations. With small post‐acquisition corrections for motion, whole‐breast 3DUS imaging was performed on the healthy female volunteer showing relevant anatomical structures and details. Conclusions Our spatially tracked 3DUS system shows potential utility as an alternative, accurate, and feasible whole‐breast approach with the capability for bedside POC imaging. Future work is focused on reducing misregistration errors due to motion and tissue deformations, to develop a robust spatially tracked whole‐breast 3DUS acquisition protocol, then exploring its clinical utility for screening high‐risk women with dense breasts.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.381
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.221
Teacher spread0.215 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicDigital Radiography and Breast ImagingFrench-language works237,207