Energy Audit of a Classroom in the Hot and Humid Region: Effect of Mechanical Dehumidification on Energy Consumption
Bibliographic record
Abstract
Abstract Air conditioning (AC) systems are the most energy-consuming systems in buildings in hot and humid climates. This study investigates the effect of mechanical dehumidification on the energy apportioning of the conventional cooling system in hot and humid regions. An energy audit was carried out in a classroom with a fan coil unit as a case study. Air characteristics, cooling load, and cooling capacity of the case study were measured. According to the energy audit results, for a room with 51% latent load and 49% sensible load, the mechanical dehumidification consumed 56% of cooling capacity, while 44% of cooling capacity was used for sensible cooling. It has been shown that mechanical dehumidification consumes the majority of the energy used by AC systems in hot and humid areas.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".